76
The Figure 5-35 and Figure 5-36 show that channels 1 to 16 are associated to HDD Group NO 1,
and channels 17 to 32 are associated to HDD Group NO 2. Therefore the records of channels 1
to 16 are stored into the hard disk(s) which belong to HDD Group NO 1, and the records of
channels 17 to 32 are stored into the hard disk(s) which belong to HDD Group NO 2.
Important
Once you change the HDD Group settings, system will pack the records and snapshots, and
then reboot.
Figure 5-35
Figure 5-36
5.5.2 Abnormity
Abnormity interface is shown as in Figure 5-37.
Event type: There are several options for you such as disk error, no disk, disconnection,
IP conflict and etc.
Alarm output: Please select alarm activation output port (multiple choices).
Latch: Here you can set corresponding delaying time. The value ranges from 10s-300s.
System automatically delays specified seconds in turning off alarm and activated o utput after
external alarm cancelled.
Show message: system can pop up the message in the local screen to alert you when
alarm occurs.
Alarm upload: System can upload the alarm signal to the network (including alarm centre)
if you enabled current function.
Send email: System can send out email to alert you when alarm occurs.
Buzzer: Highlight the icon to enable this function. The buzzer beeps when alarm occurs.
Summary of Contents for NVS1604HF-A
Page 1: ...1 4 8 16 Channel Real time D1 NVS User s Manual Version 1 0 0 ...
Page 44: ...44 Figure 4 21 Figure 4 22 Figure 4 23 Figure 4 24 4 5 3 Video Loss ...
Page 47: ...47 Figure 4 27 Figure 4 28 Figure 4 29 Figure 4 30 4 7 Backup ...
Page 92: ...92 Figure 6 11 ...
Page 148: ...148 Samsung HA101UJ CE 1T SATA ...