9
Figure 2-8
1) Open
REC Upgrade
, input keyboard IP address and TCP port (Default setup is 37777).
Note
If you can not use the 37777 to upgrade, it means the application layer did not boot up
properly. Please use port 3800 to upgrade. The upgrade process can become successful no
matter the application layer properly booted up or not.
2) Click
【
login
】
, system pops up the dialogue box,.
3) Input admin user name and password, click
【
OK
】
. The
【
login
】
button becomes
【
logout
】
if you successfully logged in.
4) Click
【
Open files
】
button to select the upgrade file.
5) Click the button
【
Bios
】
at the bottom of the interface, you can complete the upgrade
process.
2.3.1.6 Logo update
The logo upgrade function is for speed dome keyboard or analog keyboard series product. You
can update
logo.bin
file if necessary.
2.3.2 Zone (Control Point)
It is to set control point information. See Figure 2-9. All the items listed below shall be set. You
can use the ID, device name, COM address or the IP address to search a device easily in
chapter 2.4.
Figure 2-9
The information you input here shall be unique. Otherwise, system can not save the
setup.
Please make sure the com type and then parameters you set here is the same as the
actual situations. Otherwise, the keyboard can not control the device!