5.3.3.3 Configuring System Event Settings
Select
SETUP > EVENT > ABNORMAL
.
Step 1
The
HardDisk
interface is displayed. See Figure 5-79.
Abnormal event settings
Figure 5-79
Select the
Enable
check box.
Step 2
Configure the parameters. For details, see Table 5-31.
Step 3
Table 5-31 Abnormal event setting parameters description
Parameter
Description
Event Type
You can configure the corresponding abnormal events on following three
tabs.
HardDisk: Includes No HDD, HDD Error, HDD No Space.
User: Includes Illegal login.
Device: Includes Temperature Too High, Battery Low Voltage, Over
Speed, Low Speed, Collision, Turnover, Rapid Turn, Rapid Speedup,
and Rapid Slowdown.
The supported event type might be different depending on the model you
purchased, and the actual interface shall prevail.
Attempt(s)
If
Illegal Login
is selected, configure this parameter.
In the
Attempt(s)
box, enter the maximum number of allowed password
input errors. If the number of password input errors reaches this value,
the user account will be locked.
Lock Time
If
Illegal Login
is selected, configure this parameter.
If the number of password input errors reaches this value, the user
account will be locked.
Max
Temperature
If
Temperature Too High
is selected, configure this parameter.
Enter the upper limit of Device temperature. The alarm is triggered when
the Device temperature exceeds this value.
Less Than
If
Battery Low Voltage
is selected, configure this parameter.
In the
Battery Voltage
boxes, enter the minimum percentage of supply
voltage and supply voltage to the Device from vehicle. When the vehicle
ACC status is Off, the voltage supplied to the Device is lower than set
minimum percentage, the system generates alarm.
Battery Voltage