26
Figure 4-11
Parameter
Note
Work Mode
Select work mode, include
:
Off
:
NO light off
Always
:
NO light on
Auto
:
auto enable NO light according to time or brightness.
Note:
This function is for ITC237-PU1B-L only.
Light Brightness
Set light brightness, range 0
~
20.
Light Arr Mark
On light group, there are 3 groups for selection.
Auto Mode
When work mode is
“auto”, select NO light time and brightness.
Time
:
set NO light period. You can set 7 days in a week
independently with six periods per day.
Brightness
:
set preset brightness, range 0
~
100.
Note:
This function is for ITC237-PU1B-L only.
Table 4-5
’
Click Time to set time.
4.1.6 Plate White/Black List
4.1.6.1 White List
Select Setup>ITC>BW List.
Enable white list, when system detects vehicle in the white list, barrier is off.
Set white list match mode.