background image

 

10

 

 

 4/6/L6-zone digital panel (ISC-D206) 

Figure 3-3

 

 4/6/L6-zone panel description (ISC-D206) 

Figure 3-4

No.

 

Name

 

   

Four-in-one digital tube. 

 

Four-in-one digital tube. 

 

Working indicator light. 

 

Power button. 

 

– 

 

 

Program. 

3.1.2 Basic Operations 

Starting the Device 

Connect the power supply, press and hold the Reset/Switch button, and then the Device starts 

and enters the working state, and shows "0000 0000". 

Entering Password 

When  the  screen  shows  "0000  0000",  press  Program,  and  then  the  screen  shows  "P  0000". 

enter the password, press + to change the value of the corresponding bit (0 to 9 in cycle), press 

To change the bit, press 

–. If the password is correct, press Program to go next; otherwise you 

cannot go next, and the Device shows "P 0000". 

 

Keep your password in mind. 

Changing Password 

  When the screen shows "0000 0000" after power-on, press and hold Program for 3 s. 

Step 1

  When the screen displays "P 0000", enter the old password (press 

– to change the bit, 

Step 2

and press + to change the value). 

  Press Program, and then the screen displays "C- - - - ". Press +, and then the screen 

Step 3

shows "P 0000". 

Summary of Contents for ISC-D218

Page 1: ...Walk through Metal Detector Quick Start Guide V1 0 0...

Page 2: ...result in property damage data loss lower performance or unpredictable result TIPS Provides methods to help you solve a problem or save you time NOTE Provides additional information as the emphasis an...

Page 3: ...tual product and the manual Please contact the customer service for the latest program and supplementary documentation There still might be deviation in technical data functions and operations descrip...

Page 4: ...not disassemble the Device Transport use and store the Device under the allowed humidity and temperature conditions Electrical Safety Use the battery of specified manufacturer otherwise there might re...

Page 5: ...ecking List 3 2 1 Structure 3 2 2 Installation Environment 4 2 3 Installing the Device 5 2 4 3 Configuration 9 ISC D206 9 3 1 3 1 1 Configuration Panel 9 3 1 2 Basic Operations 10 3 1 3 Configuring Fu...

Page 6: ...to use it The Device can be widely used in sports meetings conferences schools and other occasions It adopts electromagnetic field to detect carry on metal articles and uses sound and light alarm to i...

Page 7: ...regnant women floppy disks film and videotapes Application Scenario 1 4 The Device is used to detect the metal items carried by the person going through the detection door Typical application scenario...

Page 8: ...ales service personnel Table 2 1 Checking list Order List Description 1 Overall packaging Appearance Obvious damage Packaging Accidental impact Accessories list of accessories on warranty card Complet...

Page 9: ...ance The actual installation distance depends on the installation site conditions Keep away from moving metal objects Large moving metal objects should be kept 0 5 m to 2 m away from the detection doo...

Page 10: ...her the package is complete and open the box Step 1 Open the box Figure 2 2 Take out the left and right door panels from the box Step 2 Take out door panels Figure 2 3 Take out the manual beam host bo...

Page 11: ...wer supply Figure 2 4 Follow the previous figure to prepare the door panels beams host box and bolts Step 4 Prepare the parts and the tools Figure 2 5 Install the beams and the host box Step 5 Install...

Page 12: ...box to the left and right door panels Step 6 Connect the detection wire Figure 2 7 Stand the Device up Step 7 Stand the Device up Figure 2 8 Connect the power supply to the Device and then turn on the...

Page 13: ...8 Start the Device Figure 2 9...

Page 14: ...tion Panel Single zone panel ISC D206 Figure 3 1 Single zone panel description ISC D206 Figure 3 2 No Name Four in one digital tube Four in one digital tube Working indicator light Save and exit Progr...

Page 15: ...ws 0000 0000 press Program and then the screen shows P 0000 enter the password press to change the value of the corresponding bit 0 to 9 in cycle press To change the bit press If the password is corre...

Page 16: ...ogram to save when finishing each configuration Function configuration Figure 3 6 Table 3 1 Function description No Function description Number of passes Number of alarms Function configuration Parame...

Page 17: ...s available for Zone 3 0 200 200 levels available for Zone 4 0 200 200 levels available for Zone 5 Configure the duration of the alarm sound 1 3 3 levels available Configure alarm volume 0 2 2 levels...

Page 18: ...it 0 to 9 in cycle Press to change the bit If the password is wrong you get the prompt C333 Press and enter the password again Only when the password is correct can you press to enter the parameter ad...

Page 19: ...available for Detector 5 Configure alarm volume 0 99 100 levels available Configure alarm tone 0 99 100 levels available Configure the duration of the alarm sound 0 99 100 levels available Configure s...

Page 20: ...nter 14 Metals factory 38 Meeting room 62 Subway station 15 Electronics factory 39 VIP room 63 Villa 16 Precision instrument factory 40 Office 64 Community 17 Industry mine 41 Rescue station 65 Opera...

Page 21: ...or code Figure 4 1 Table 4 1 Error code description Code Description E R R Error 1 L Detector 1 on the left door 2 L Detector 2 on the left door 1 R Detector 1 on the right door 2 R Detector 2 on the...

Page 22: ...ed on 1 Check whether the power cable between the host box and the detection door and the door 220V AC power cord are well connected 2 Check the power adapter for breakage or poor contact and whether...

Page 23: ...ration False alarm Automatic alarms occur when no one goes through the machine 1 Check whether the environment around the detection door affects the detection door and try to change the frequency 2 Fa...

Page 24: ...s function to obtain timely information of firmware updates released by the manufacturer We suggest that you download and use the latest version of client software Nice to have recommendations to impr...

Page 25: ...TLS to access mailbox server FTP Choose SFTP and set up strong passwords AP hotspot Choose WPA2 PSK encryption mode and set up strong passwords 11 Audio and Video Encrypted Transmission If your audio...

Page 26: ...achieve the network isolation effect Establish the 802 1x access authentication system to reduce the risk of unauthorized access to private networks It is recommended that you enable your device s fir...

Reviews: