background image

                                                                           

 

 

12 

6

 

FAQ 

Bug  

 

I can not boot up 
the device or 
operate properly. 

Please click RESET button for at least five seconds to restore 
factory default setup. 

The water leakage 
occurred. 

 

The unauthorized front or rear cap remove many result in water 
leakage. 

 

The glass front cap has sustained heavy push or strike. 

 

The waterproof plug of the rear cap becomes loosen. 

IR video is poor. 

 

Did not use the proper supplying power. The IR light can not 
turn on completely. 

 

The object is out of the IR distance range of current device. 

 

IR-CUT does not turn to the night mode. The photosensitive 
chip of the front-end can not sense the IR light.  

I  can  not  upgrade 
the 

device 

via 

network. 

When network upgrade operation failed, you can use port 3800 to 
continue upgrade.  

I can not login the 
client-end or the 
WEB. 

 

For Windows OS 98 or Windows ME user, if you can not install 
the client-end or can not view after the installation. We 
recommend the 

w

in2000 sp4 OS or higher, or install the client-

end of the low version. 

 

The Active X control is blocked. 

 

The display card version shall be dx8.1 or higher. 

 

Network connection error occurred. 

 

Invalid network setup. 

 

Invalid user name or password.  

I can not play the 
download file.  

 

There is no player. 

 

There is no DX8.1 or higher. 

 

For the MEDIA PLAYER, there shall be Div X503Bundle.exe 
plugin if you play the .AVI file. 

 

For Windows XP user, you need to install the plugin 
DivX503Bundle.exe and ffdsho-2004 1012.exe. 

To guarantee 
setup update 

After you modified the important setup, please reboot the device via 
the software to make sure the setup has been updated to the 
storage medium.  

Power adapter 

 

The general power adapter can work ranging from 0

 to 40 

The device may result in unstable power supply when the 
temperature exceeds the working temperature.  

 

Please replace an industry-level power adapter if you are using 
in the harsh environments.  

 

Summary of Contents for IPC-HFW4100EP

Page 1: ...HD Mini IR Fixed Network Camera User s Manual Version 1 0 3 Zhejiang Dahua Vision Technology CO LTD ...

Page 2: ...ur network camera This user s manual is designed to be a reference tool for your system Please read the following safeguard and warnings carefully before you use this series product Please keep this user s manual well for future reference ...

Page 3: ...on Please install the proper power cut off device during the installation connection Always follow the instruction guide the manufacturer recommended 4 Qualified engineers needed All the examination and repair work should be done by the qualified service engineers We are not liable for any problems caused by unauthorized modifications or attempted repair 5 Environment This series network camera sh...

Page 4: ... not touch the enclosure when you are installing the device or clean the enclosure when you are doing maintenance work Please use professional optical clean method to clean the enclosure Improper enclosure clean method such as use cloth may result in poor IR effect of camera with IR function 7 Accessories Be sure to use all the accessories recommended by manufacturer Before installation please ope...

Page 5: ...1 3 1 Performance 2 2 Framework 4 2 1 Cable 4 2 2 Framework and Dimension 4 3 Device Installation 6 4 Quick Configuration Tool 8 4 1 Overview 8 4 2 Operation 8 5 Web Operation 10 5 1 Network Connection 10 5 2 Login and Main Interface 10 6 FAQ 12 Appendix Toxic or Hazardous Materials or Elements 13 ...

Page 6: ...he user right shall not exceed the group right Storage Function Support central server backup function in accordance with your configuration and setup in alarm or schedule setting Support record via Web and the recorded file are storage in the client end PC Support network storage function such as FTP Data Transmission Support data transmission via Ethernet Network Monitor Network camera supports ...

Page 7: ...ode Support day night mode switch Gain Control Fixed Auto White Balance Manual Auto BLC On Off Exposure Mode Auto Low noise Low motion blur Manual It ranges from 1 3 to 1 100000 Video Compression Standard H 264 H 264H MJPEG Video Frame Rate PAL Main stream 1280 960 25 fps extra stream 1 704 576 25fps extra stream 2 1280 720 8fps PAL Main stream 1920 1080 2 5fps extra stream 1 704 576 25fps extra s...

Page 8: ...ct 396 18 22 detection zones sensitivity level ranges from 0 to 100 area threshold ranges from 0 to 100 Activation event video storage image snapshot log email function and etc Record and Backup Record Priority Manual Video detect Schedule Storage Management NAS storage Network Wire Network 1 channel wire Ethernet port 10 100 Base T Ethernet Network Protocol Standard HTTP TCP IP ARP IGMP ICMP RTSP...

Page 9: ...ion No Port Name Function Connection Note 1 LAN Network port Ethernet port Connect to standard Ethernet cable Note Before making crystal head pull the anti dust cover through network cable 2 DC 12V Power input port Power port Input DC 12V 2 2 Framework and Dimension Please refer to the following figure for dimension information The unit is mm See Figure 2 2 and Figure 2 3 ...

Page 10: ...5 Figure 2 2 Dimension illustration 1 Figure 2 3 Dimension illustration 2 ...

Page 11: ...all the device wall or ceiling Step 2 Dig a hole according to position of hole on installation sticker Step 3 Open accessories bag take out expansion bolt and insert it into the hole you just dug Step 4 Open accessories bag take out screw Tighten the 4 screws to fix the device on the installation surface wall or ceiling You can move device sunshade back and forth When you have fixed the device you...

Page 12: ...ou are done When the camera body and installation chassis form a 90 angle and adjusting screw is tight please do not rotate the camera body over 360 Step 6 Use wobbler driver in accessories bag to loosen adjusting screw Step 7 Adjust the device in all possible directions and set its monitoring direction Step 8 Use wobbler driver to tighten the screws ...

Page 13: ...wn as in Figure 4 1 In the device list interface you can view device IP address port number subnet mask default gateway MAC address and etc Figure 4 1 Search interface Select one IP address and then right click mouse you can see an interface is shown as in Figure 4 2 Select the Open Device Web item you can go to the corresponding web login interface Figure 4 2 Search interface 2 If you want to mod...

Page 14: ...o login Please note the port information here shall be identical with the port value you set in TCP port in Web Network interface Otherwise you cannot login the device If you are using device background upgrade port 3800 to login other setups are all invalid Figure 4 3 Login prompt After you logged in the configuration tool main interface is shown as below See Figure 4 4 Figure 4 4 Main interface ...

Page 15: ... the PC and the network camera respectively Network camera default IP address is 192 168 1 108 Subnet mask is 255 255 255 0 Gateway is 192 168 1 1 Use order ping network camera address to check connection is OK or not 5 2 Login and Main Interface Open IE and input network camera address in the address bar See Figure 5 1 Figure 5 1 IP address The login interface is shown as below See Figure 5 2 Ple...

Page 16: ...ogin After you successfully logged in please install WEB plug in unit Please refer to the Web Operation Manual included in the resource CD for detailed operation instruction See Figure 5 3 Figure 5 3 Web monitoring window ...

Page 17: ... you can not install the client end or can not view after the installation We recommend the win2000 sp4 OS or higher or install the client end of the low version The Active X control is blocked The display card version shall be dx8 1 or higher Network connection error occurred Invalid network setup Invalid user name or password I can not play the download file There is no player There is no DX8 1 ...

Page 18: ...f these substances or elements will not result in any severe environmental pollution any bodily injury or damage to any assets The consumer is not authorized to process such kind of substances or elements please return to the corresponding local authorities to process according to your local government statutes Note This user s manual is for reference only Slight difference may be found in user in...

Reviews: