NTSC: 
Main stream

3M@15fps ,10

80P@30fps, 
SXGA@30fps, 
1.3M@30fps, 
720P@30fps, 
704*480@30fps

),

 

Extra stream

704*480@30f

ps,352*240@30f
ps

 

NTSC: 
Main stream 

1080P@30fps, 

SXGA@30fps, 
1.3M@30fps, 
720P@30fps, 
704*480@30fps

),

 

Extra stream 

704*480@30fp

s,352*240@30fps

 

 

NTSC: 
Main stream

 

1.3M@30fps, 

720P@30fps, 
704*480@30fp
s

 

Extra stream 

704*480@30f

ps,352*240@3
0fps

 

 
 
 

NTSC: 
Main stream

 

1.3M@30fps, 

720P@30fps, 
704*480@30fp
s

 

Extra stream 

704*480@30

fps,352*240@3
0fps

 

 
 
 

Video Bit Rate 

H.264: 56Kbps-8192Kbps.   

JPEG is adjustable and bit rate is adjustable.  

Support customized setup. 

Video Flip 

Support mirror.  
Support flip function. 

Snapshot 

Max 1f/s snapshot. File extension name is JPEG. 

Privacy Mask 

Supports max 4 privacy mask zones  

Video Setup 

Support parameter setup such as bright, contrast. 

Video 
Information 

Channel title, time title, motion detect, camera masking. 

Lens 

 

[email protected] 

2.8-
[email protected] 

Lens Interface 

Φ

14 interface. Lens is the default accessories  

Audio Input 

1-channel. RCA 

Audio Output  

1-channel. RCA 

Bidirectional 
Talk Input 

Reuse the first audio input channel 

Audio Bit Rate 

16kbps  16BIT 

   

 Audio  

Audio 
Compression 
Standard 

G.711a/G.711u/PCM 

   

 Video  

Motion Detect 

396 (18*22)  detection zones

sensitivity level ranges from  1 to 6 (The 6

th

  

level has the highest sensitivity) 
Activation event: alarm device, audio/video storage, image snapshot, log, 
email function and etc. 

Alarm Input  

2-channel input

1-channel output 

Record Priority  

Manual>External alarm >Video detect>Schedule 

Local Storage 

Support Micro SD card storage 

Record and 

Backup  

Storage 
Management 

Support display local storage status  

Wire Network  

1-channel wire Ethernet port, 10/100 Base-T Ethernet 

Network Protocol 

Standard HTTP, TCP/IP, ARP, IGMP, ICMP, RTSP, RTP,UDP, RTCP, 
SMTP, FTP, DHCP, DNS, DDNS, PPPOE, UPNP, NTP, Bonjour, SNMP. 

  Network  

Remote 
Operation 

Monitor, PTZ control, system setup, file download, log information, 
maintenance , upgrade and etc. 

Video Output 

1-channel analog video output

BNC port. 

 AUX 

Interfac

Restore Default 
Setup  

Reset button  

Summary of Contents for IPC-HFW3300C

Page 1: ...HD IR Waterproof Fixed IP Camera With Integrated Bracket User s Manual Version 3 2 3...

Page 2: ...our IP camera This user s manual is designed to be a reference tool for your system Please read the following safeguard and warnings carefully before you use this series product Please keep this user...

Page 3: ...on connection Always follow the instruction guide the manufacturer recommended 4 Qualified engineers needed All the examination and repair work should be done by the qualified service engineers We are...

Page 4: ...to clean the device Please put the dustproof cap to protect the CCD CMOS component when you do not use the camera 7 Accessories Be sure to use all the accessories recommended by manufacturer Before i...

Page 5: ...n Combination Cable 11 2 2 Framework and Dimension 12 2 3 Bidirectional talk 13 2 3 1 Device end to PC end 13 2 3 2 PC end to the Device end 13 2 4 Alarm Setup 13 3 Device Installation 15 4 Quick Conf...

Page 6: ...z The user right shall not exceed the group right Storage Function z Support central server backup function in accordance with your configuration and setup in alarm or schedule setting z Support recor...

Page 7: ...atistics log and software version Image Sensor 1 2 8 inch CMOS 1 2 8 inch CMOS 1 3 inch CMOS 1 3 inch CMOS Pixel 2080 H 1553 V 1920 H 1080 V 1280 H 960 V 1280 H 960 V Day Night Mode Support day night...

Page 8: ...14 interface Lens is the default accessories Audio Input 1 channel RCA Audio Output 1 channel RCA Bidirectional Talk Input Reuse the first audio input channel Audio Bit Rate 16kbps 16BIT Audio Audio C...

Page 9: ...ry default setup information Default Setup Setup Item IPC HFW3300C IPC HFW3200C IPC HFW3100C IPC HFW3101C Brightness 50 Contrast 50 Hue 50 Saturation 50 Gain Mode Auto Gain Adjust 80 Exposure Mode Aut...

Page 10: ...am I Frame 50 Snapshot Type General Image Size 1080P 1920 1080 1080P 1920 1080 1 3M 1280 960 720P 1280 720 Quality 5 Snapshot Interval 1s Privacy Mask Disable Channel Title Enable Video Overlay Time T...

Page 11: ...able ARP Ping set device IP address service Enable Max Connection 10 TCP Port 37777 UDP Port 37778 HTTP Port 80 Connection RTSP Port 554 Enable Disable Username none PPPoE Password N A Server Type Dis...

Page 12: ...0 minutes UPnP Enable UPnP Disable SNMP v1 Disable SNMP v2 Disable SNMP Port 161 Read Community public Write Community private Trap Address N A SNMP Trap Port 162 Enable Enable Bonjour Server Name MAC...

Page 13: ...le Relay in Alarm 1 Anti dither 0 seconds Sensor Type NO Record Channel Enable Record Delay 10 seconds Relay out Enable Alarm Delay 10 seconds Send Email Disable Alarm Activation Snapshot Disable Alar...

Page 14: ...Enable IP Conflict Relay out Delay 10 seconds Enable FTP Disable Server IP N A Port 21 Username anonymity Password N A Remote path share Storage FTP Emergency Local Disable Pack Duration 8 minutes Pr...

Page 15: ...W3101C DST Disable DST Type Week Start Time 00 00 00 of the first Sunday of the month End Time 00 00 00 of the second Monday of the month NTP Disable NTP Server clock isc org Port 37 Update Period 10...

Page 16: ...o AUDIO IN Audio input port RCA Input audio signal It can receive the analog audio signal from the pickup AUDIO OUT Audio output port RCA Output audio signal to the devices such as the sound box DC 12...

Page 17: ...LARM_COM port 3 ALARM_IN1 Alarm input port 1 It is to receive the on off signal from the external alarm source 4 ALARM_IN2 Alarm input port 2 It is to receive the on off signal from the external alarm...

Page 18: ...ter you enabled the audio talk function Click Audio button again to stop the bidirectional talk function Please note the listening operation is null during the bidirectional talk process Listening Ope...

Page 19: ...le the device collects the logic 1 When the input signal is grounded the device collects the logic 0 Figure 2 5 Please refer to the following figure for alarm output information See Figure 2 6 Port NO...

Page 20: ...tion surface and then mark three expansion bolts holes in the surface Insert three bolts in the hole and secure firmly z Please line up the installation holes of the bottom of the pendant mount bracke...

Page 21: ...y applies to the IP addresses in the same segment 4 2 Operation Double click the ConfigTools exe icon you can see an interface is shown as in Figure 4 1 In the device list interface you can view devic...

Page 22: ...terface Or you can select an IP address and then click the Login button to go to the login interface See Figure 4 4 In Figure 4 4 you can view device IP address user name password and port Please modi...

Page 23: ...18 Figure 4 5...

Page 24: ...y IPC default IP address is 192 168 1 108 Subnet mask is 255 255 255 0 Gateway is 192 168 1 1 z Use order ping IP camera address to check connection is OK or not 5 2 Login and Logout Open IE and input...

Page 25: ...se click OK button system can automatically install the control When system is upgrading it can overwrite the previous Web too If you can t download the ActiveX file please check whether you have inst...

Page 26: ...21 Figure 5 4 Please refer to the Web Operation Manual included in the resource CD for detailed operation instruction...

Page 27: ...r higher high speed card in case the slow speed results in data loss Audio function Please use active device for the audio monitor input otherwise there is no audio in the client end To guarantee setu...

Page 28: ...iod the toxic or hazardous substance or elements contained in products will not leak or mutate so that the use of these substances or elements will not result in any severe environmental pollution any...

Reviews: