background image

                                                                           

 

Appendix Toxic or Hazardous Materials or Elements 

Component Name 

Toxic or Hazardous Materials or Elements 

Pb 

Hg 

Cd 

Cr VI 

PBB 

PBDE 

Circuit Board Component 

○ 

○ 

○ 

○ 

○ 

○ 

Device Case 

○ 

○ 

○ 

○ 

○ 

○ 

Wire and Cable 

○ 

○ 

○ 

○ 

○ 

○ 

Packing Components 

○ 

○ 

○ 

○ 

○ 

○ 

Accessories 

○ 

○ 

○ 

○ 

○ 

○ 

O: Indicates that the concentration of the hazardous substance in all homogeneous materials in the 

parts is below the relevant threshold of the SJ/T11363-2006 standard. 

 

X: Indicates that the concentration of the hazardous substance of at least one of all homogeneous 

materials in the parts is above the relevant threshold of the SJ/T11363-2006 standard. During the 

environmental-friendly use period (EFUP) period, the toxic or hazardous substance or elements 

contained in products will not leak or mutate so that the use of these (substances or elements) will not 

result in any severe environmental pollution, any bodily injury or damage to any assets.  The consumer 

is not authorized to process such kind of substances or elements, please return to the corresponding 

local authorities to process according to your local government statutes. 

 

Note 

 

This user’s manual is for reference only. Slight difference may be found in user 

interface. 

 

All the designs and software here are subject to change without prior written 

notice. 

 

All trademarks and registered trademarks mentioned are the properties of their 

respective  

owners. 

 

If there is any uncertainty or controversy, please refer to the final explanation of 

us. 

 

Please visit our website for more information. 

 
 

 

12 

Summary of Contents for EBW8600

Page 1: ...HD Fisheye Panorama Network Camera Quick Start Guide Version 1 1 0 i...

Page 2: ...esponsibility for all the fires or electrical shock caused by improper handling or installation We are not liable for any problems caused by unauthorized modification or attempted repair 2 Transportat...

Page 3: ...mponent You can use the blower to clean the dust on the lens surface Always use the dry soft cloth to clean the device If there is too much dust please use the water to dilute the mild detergent first...

Page 4: ...General Installation 4 2 2 Device Installation Steps 4 2 3 Micro SD Card Installation 5 2 4 Manual Zoom Lens Focus Operation 6 3 Quick Configuration Tool 7 3 1 Overview 7 3 2 Operation 7 4 Web Operati...

Page 5: ...o signal receive the analog audio signal from the sound pick up 3 LAN Network port Ethernet port Connect to standard Ethernet cable 4 I O I O port Connect I O port 5 POWER Power input port Connect DC...

Page 6: ...wo standards for side dimension of the device which are 33 7mm 47 7mm and 36 6mm 50 7mm Please refer to the actual product model for more details You can refer to the following figures for dimension i...

Page 7: ...he same time for the device Listening Operation At the PC end speak via the speaker or MIC and then you can get the audio at the device end 1 4 Alarm Setup Please refer to Figure 1 5 for more informat...

Page 8: ...tallation information You can see there are installation screws in the accessories bag for you to install the device conveniently Figure 2 1 2 2Device Installation Steps Step 1 Take the installation p...

Page 9: ...corresponding to the TOP direction on the installation chassis rotate the dome body in clockwise direction and secure it firmly So far installation is completed Note Please refer to Micro SD card inst...

Page 10: ...sten the screws tightly to prevent dust Figure 2 3 2 4Manual Zoom Lens Focus Operation The lens of the HD panorama dome network camera is 360 no manual zoom is required when it is operated by in ceili...

Page 11: ...gure 3 1 In the device list interface you can view device IP address port number subnet mask default gateway MAC address and etc Figure 3 1 Select one IP address and then right click mouse you can see...

Page 12: ...ote the port information here shall be identical with the port value you set in TCP port in Web Network interface Otherwise you cannot login the device If you are using device background upgrade port...

Page 13: ...rk camera default IP address is 192 168 1 108 Subnet mask is 255 255 255 0 Gateway is 192 168 1 1 Use order ping network camera address to check connection is OK or not 4 2Login and Main Interface Ope...

Page 14: ...re 4 2 After you successfully logged in please install WEB plug in unit Please refer to the Web Operation Manual included in the resource CD for detailed operation instruction See Figure 4 3 Figure 4...

Page 15: ...0 degrees panorama Dual picture panorama It is the dual window 180 degrees panorama 1 window It is to display one of the four windows It can show the video around the 360 degrees panorama You can sele...

Page 16: ...ic or hazardous substance or elements contained in products will not leak or mutate so that the use of these substances or elements will not result in any severe environmental pollution any bodily inj...

Reviews: