74
Figure 5-29
Click alarm set button, the interface is shown as below. See
434H434H
Figure 5-30(This
interface is just like the abnormity setup).
Please highlight icon
to select the corresponding function.
You can enable one or more alarm setups. The lower limit ranges from 1% to 99%.
Alarm channel number ranges from 1 to 6. Delay value is from 0 to 240 seconds.
Please note when HDD capacity is not full system only alarms once!
After all the setups please click OK button, system goes back to the previous menu
Figure 5-30
5.5.2 Abnormity
Abnormity interface is shown as in
435H435H
Figure 5-31.
z
Event type: There are several options for you such as disk error, no disk and
etc.
z
Alarm output: alarm activation output port (multiple choices), among which is
controllable 12V output.
z
Latch: here you can set corresponding delaying time. The value ranges from 10s-
300s. System automatically delays specified seconds in turning off alarm and
activated output after external alarm cancelled.
z
Show message: system can pop up the message in the local screen to alert
you when alarm occurs.
z
Send email: System can send out email to alert you when alarm occurs.