User’s Manual
16
Parameter
Description
1, 2
Set barrier control mode.
1/OFF and 2/ON (recommended): The Barrier receives
opening and closing signals, and automatically opens when
vehicle passes, and closes after vehicle leaves.
1/OFF and 2/OFF: The Barrier receives opening and closing
signals, but does not automatically open or close.
1/ON and 2/OFF: The Barrier keeps open. It temporarily
closes when there are continuous close signals.
1/ON and 2/ON: The Barrier keeps closed. It temporarily
opens when there are continuous opening signals.
3
ON by default.
4
Set counting function.
ON: Enable counting function. After receiving N opening
signals, the barrier closes only after N vehicles pass.
OFF (recommended): Disable counting function.
5, 6
OFF by default.
7
Set auto barrier opening in case of power failure.
7/ON: Enable auto barrier opening in case of power failure.
7/OFF: Disable auto barrier opening in case of power failure.
8, 9, 10
OFF by default.
Buttons
Open barrier.
Close barrier.
Pair with remote control.
Press it for 1 s, and when the RUN indicator flashes, press and
hold the open or close button on the remtoe control for 3 s to start
pairing with the remote control.
Clear remote control information.
Press and hold it for 5 s, and after the RUN indicator flashes 10 s,
the information of the paired remote control will be cleared.
Press it to reset the barrier inverter.
Indicators
GOUP
The indicator is on when there is opening signal.
GODN
The indicator is on when there is closing signal.
VD
Vehicle signal indicator.
The indicator is on when there is 24V voltage signal for the vehicle
signal port, and it is off when there is no such signal.
RUN
Indicates system activity status and remote control pairing status.
The indicator flashes when it works normally.