Dahua DH-TPC-PT8320B Quick Start Manual Download Page 4

 

 

iii 

Important Safeguards and Warnings  

Safety Measures  

1. Qualified Engineer Needed  

 

The installation engineer or maintenance engineer shall have corresponding CCTV system 

installation certificate or maintenance qualification certificate.  

 

The installation engineer or maintenance engineer shall have qualification certificate for work 

at height.  

 

The installation engineer or maintenance engineer shall have the basic knowledge and 

operation technique for low-voltage cable layout and low-voltage electronic cable connection. 

 

Please read the installation manual carefully and keep it well for future reference, 

 

We are not liable for any problems caused by unauthorized modifications or attempted repair.

 

 

2. Lifting Appliance Requirement  

 

Please select the proper thermal hybrid dome installation mode and use the lifting 

appliances at the safety environment. 

 

The lifting appliances shall have the enough capacity to reach the installation height. 

 

The lifting appliances shall have safe performance.  

 

 

The precaution measures include two types: Warning and Note. 

 

Warning

: It is to alert you there is an optional risk of death or series injury! 

 

Note

: It is to alert you there is an optional risk of damage or property loss! 

 

Warning 

1.  All installation and operation here should conform to your local electrical safety codes. We 

assume no liability or responsibility for all the fires or electrical shock caused by improper 

handling or installation.  

2.  Be sure to use all the accessories (such as power adapter) recommended by manufacturer. 

3.  Do not connect several thermal hybrid domes to one power adapter. It may result in 

overheat or fire if it exceeds the rated load.  

4.  Avoid aiming the lens at the strong radiation source directly (such as sun, laser, molten steel 

etc); in case it may cause unrecoverable damage to the thermal imaging detector. What

’s 

worse, it may cause severe damage to the detector.  

5.  Avoid oil stain and kinds of chemicals tarnishing and damaging the lens surface. 

6.  Store  the  device  in  a  cool  and  dry  place  where  there  is  ventilation  but  no  intense 

Summary of Contents for DH-TPC-PT8320B

Page 1: ...Thermal Hybrid PTZ Camera Quick Start Guide Version 1 0 0 ...

Page 2: ...ce and intension 1 1 1 2 About cable 1 2 SETUP BEFORE INSTALLATION 2 2 1 Check Accessories 2 2 2 PTZ Dimension 2 3 INSTALLATION 3 4 NETWORK CONFIGURATION 5 4 1 Modify IP Address 5 4 2 Login WEB Interface 6 5 APPENDIX Ⅰ LIGHTENING PROTECTION AND SURGE PROTECTION 8 6 APPENDIX ǁ PROBLEMS AND SOLUTIONS 9 ...

Page 3: ...ii Welcome Thank you for purchasing our thermal hybrid dome Please read the following safeguards and warnings carefully before you install or use the product ...

Page 4: ...stallation height The lifting appliances shall have safe performance The precaution measures include two types Warning and Note Warning It is to alert you there is an optional risk of death or series injury Note It is to alert you there is an optional risk of damage or property loss Warning 1 All installation and operation here should conform to your local electrical safety codes We assume no liab...

Page 5: ...function Shut down the device and disconnect the power cable immediately if there is smoke abnormal smell or abnormal function Please contact your local retailer ASAP 3 Do not try to dismantle or modify the device There is risk of personal injury or device damage resulting from opening the shell Please contact your local retailer if there is internal setup or maintenance requirement We are not lia...

Page 6: ...he soft cloth to clean dust on the shell or you can use soft cloth with cleaning liquid to clean the shell and then use soft cloth to make it dry Do not use gasoline dope thinner or other chemical material to clean the shell It may result in shell transfiguration or paint flake Do not allow the plastic or rubber material to touch the shell for a long time It may result in paint flake ...

Page 7: ...he following requirements when users need to extend the power cable The recommended max transmission distance is shown in the following sheet when the wire diameter is fixed and 24V AC or 24V DC voltage loss rate is lower than 10 Wire diameter mm Max distance ft m 1 000 22ft 6m 1 250 35ft 10m 2 000 90ft 27m Select required signal cable All the signal cables audio alarm input output RS485 and etc a...

Page 8: ...nd the PTZ are separately packed when the device leaves factory please check the packing list for the first installation Please contact the customer service if there is anything missing 2 2 PTZ Dimension Please refer to Figure 2 1 for the device dimension Figure 2 1 ...

Page 9: ...owed to power up before it is fixed on the installation platform otherwise the device may turn over and cause damage to the lens during power on self test for the device Figure 3 1 The installation steps are as follows Step 1 Use the inner hex wrench from in the PTZ accessories bag to loosen the screws on both sides of the housing bracket and take off the housing bracket Step 2 Use the screws in t...

Page 10: ... Step 7 It can extend PTZ cable properly according to the actual construction needs the device is equipped with power adapter by default and please consult related personnel in our company when using other adapters before installation The extended cable needs to be prepared by users themselves refer to the chapter 1 1 2 for more details about the cable ...

Page 11: ...onnect the PC to the device directly via network cable Step 2 Double click the ConfigTools exe and open the quick configuration tool Step 3 Double click the device to be configured the system will pop out the Login dialog box Enter the IP address user name password and port number of the camera and click OK Note The default user name and password are admin and admin respectively the default port i...

Page 12: ...r to the WEB Operation Manual in the disk and the actual interface for more details Step 1 Open IE and input the modified camera IP address in the address bar Step 2 The login interface is shown below please input your user name and password Default user name is admin and password is admin respectively click login See Figure 4 3 for more details ...

Page 13: ...re 4 3 Step 3 Install controls according to the system prompt see Figure 3 4 for the WEB main interface Please modify the administrator password as soon as possible after you successfully logged in Figure 4 4 ...

Page 14: ...nd connects one point to the earth Open floor cable layout is forbidden In area of strong thunderstorm hit or near high sensitive voltage such as near high voltage transformer substation you need to install additional high power thunder protection device or lightning rod The thunder protection and earth of the outdoor device and cable shall be considered in the building whole thunder protection an...

Page 15: ... Video switch or power problem Need electrical engineer help 5 Video is not clear Focus is in manual mode Control manually PTZ cover is dirty Wash PTZ cover 6 During PTZ switch there is a tilt movement in the monitor Camera power is not in the same Phase When several PTZs are connected to one transformer please connect the transformer output cable to the domes same side 7 The PTZ keeps rotating an...