background image

 

36 

System Diagram (Economical Proposal)

 

 

Appendix Figure 1-2 

With point-to-point transmission, receiving end adopts DH-PFM881 device.   

No.

 

Type 

 

Model No.

 

Qua
ntity

 

Description 

 

Feature 

 

1

 

Wireless 
receiving 
end 

DH-PFM881 

Outdoor  waterproof,  wide  temperature: 
-30~70°,  wireless  bandwidth:  300M, 
coverage  area:  3km,  standard  power 
supply 

It  applies  to 
outdoor 

high 

temperature 
and 

low 

temperature 
environment. 

2

 

Wireless 
client 

DH-PFM881 

Outdoor  waterproof,  wide  temperature: 
-30~70°,  wireless  bandwidth:  300M, 
coverage  area:  3km,  standard  power 
supply 

It  applies  to 
outdoor 

high 

temperature 
and 

low 

temperature 
environment. 

3

 

Switch  of 
machine 
room 
(optional) 

DH-S4200-24

Gigabit 

management 

switch, 

24*10/100/1000Base-T,  4*SFP(Combo) 
light,  natural  heat  dissipation  without 
fan, dustproof design 

It  applies  to 
non-standard 
machine  room 
environment. 

Appendix Table 1-2 Recommended Model Selection List of Economical Proposal 

 

 

Summary of Contents for DH-PFM88 Series

Page 1: ...DH PFM Wireless Equipment User s Manual V1 0 0 ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD...

Page 2: ...emble decode reverse engineering rent transfer or sub license the software Trademark and are trademarks or registered trademarks of the Dahua in various jurisdictions Other trademarks and company name...

Page 3: ...used regardless of the theory of liability contract tort or otherwise even if it has been advised of the possibility of such damages Some jurisdictions do not allow the exclusion or limitation of liab...

Page 4: ...the system s credentials You will need to either update the camera s firmware to the latest revision or manually change the ONVIF password 6 Forward Only Ports You Need Only forward the HTTP and TCP...

Page 5: ...activation can enhance your network security 13 Check the Log If you suspect that someone has gained unauthorized access to your system you can check the system log The system log will show you which...

Page 6: ...tial danger It will cause severe injury or casualties if it fails to avoid It means moderate or low potential danger It may cause slight or moderate injury if it fails to avoid It means potential risk...

Page 7: ...p or splash liquids onto the product Please don t put other things onto the product Please don t dismantle the product arbitrarily Please use recommended power line within rated specifications Special...

Page 8: ...ine Connection 9 2 3 Restore Factory Defaults 9 3 Common Networking 11 3 1 Wireless Point to point 11 3 2 Wireless Point to multipoint 12 3 3 Adjustment of Wireless Coverage Dead Angle 13 4 Status Dis...

Page 9: ...ardware information WEB page parameters configuration mode networking mode and fault analysis so as to effectively help users to know and use the equipment quickly and shorten the time for users to kn...

Page 10: ...tically adjusts wireless parameters and optimizes the equipment performance DH PFM881 maximum point to point transmission distance reaches 3km and maximum transmission rate reaches 300Mbps With excell...

Page 11: ...tion 3 Ping Watchdog Function Carries out Real time Detection of Link Ping Watchdog function detects whether the link fails or not and reboots the equipment immediately when the link fails so as to en...

Page 12: ...on wireless access rate wide wireless bandwidth configuration is used when there are many idle wireless channels and single user places a high requirement on wireless access rate Moreover narrow wire...

Page 13: ...ay 8 Support automatic rebooting and restoration function of the equipment 9 Full band support frequency spreading supports 4920 6100Mhz 10 Support flow control control input output flow of base stati...

Page 14: ...st 1 2 Antenna 1 N A 3 Feeder 2 Cable tie 2 4 POE power supplier 24V 0 5A 1 POE power supplier 24V 0 5A 1 5 Instruction book Instruction book 6 Other installation packages Other installation packages...

Page 15: ...eft is network indicator light and the third one is connection indicator light The first one to the third one in the right is signal strength indicator light Figure 1 1 LED Indicator Light on DH PFM88...

Page 16: ...n Diagram DH PFM88X line connection type differs under different network modes Since its default setting is network bridge mode this chapter mainly describes line connection type of network bridge mod...

Page 17: ...8 Figure 2 2 DH PFM880 Installation Diagram Figure 2 3 DH PFM881 Installation Diagram...

Page 18: ...nterface None Connect POE interface on POE power supply with network cable provide DH PFM880 equipment with 24V power supply and data transmission LAN interface on POE power supply connects a switch o...

Page 19: ...ode Client Encryption Type WPA WPA2 CCMP secret key 1234567890abc Network Mode Network bridge mode Table 2 2 Factory Defaults of Main Parameters At network management page of the equipment System Sett...

Page 20: ...AN IP 2 At Wireless Page wireless mode shall be set to be access point and client respectively AP and client have the same SSID the same encryption way and password For example WPA WPA2 CCMP 123456789...

Page 21: ...d which is disenabled by default in all equipment they have different LAN IP 2 At Wireless Page wireless mode shall be set to be access point and client respectively AP and client have the same SSID t...

Page 22: ...equipment shall adopt wired connection 2 Downlink client equipment is set to be access point uplink central AP equipment is set to be client 3 For specific configuration of single equipment please ref...

Page 23: ...esent WAN IP IP address of WAN port in route mode WAN MAC MAC address of WAN port in route mode Network Mode Operation mode route mode or network bridge mode Network Name Name of wireless network Freq...

Page 24: ...e Table 4 1 Parameters on Status Display Page Real time Monitoring Throughput rate also known as throughput capacity it refers to data size passing every section within unit time Throughput rate on st...

Page 25: ...gone through DH PFM88X in the past certain period obtained by the equipment Figure 4 5 ARP Table AP Client Information Table When the equipment connects a client in AP mode it shows client informatio...

Page 26: ...eference to Figure 2 4 DH PFM88X Interface Connection Diagram Operating Steps Step 1 Configure static IP address of 192 168 1 x segment of host IP address for example 192 168 1 180 Figure 5 1 Host IP...

Page 27: ...asic information such as working status present settings and software version of DH PFM88X equipment Figure 5 3 Status Display Step 4 Click Wizard in the left which helps the user to configure the equ...

Page 28: ...IP address of LAN port is 192 168 1 36 It is suggested that the user should modify its IP address immediately after logging onto the equipment Equipment IP is unique in the same LAN Pay attention to m...

Page 29: ...necting video camera is usually set as client mode In access point mode local DH PFM88X equipment is usually set as access point mode connecting surveillance room In case of multiple access points in...

Page 30: ...y needs to change channel width to be 40 MHz or 40 MHz set output power at 27dBm and tick ACK Timeout Adjustment Other options remain unchanged When wireless mode is client the user shall set channel...

Page 31: ...sted that the user should enable ACK Timeout Adjustment This option tests the distance between two equipment automatically sets parameters according to this distance and thus optimizes wireless connec...

Page 32: ...peater Access Point AP mode a wireless access node can be connected with client equipment such as computer mobile phone and wireless bridge etc One AP is able to connect with multiple clients CPE Clie...

Page 33: ...istance and signal strength will be enhanced Country Code different countries or regions have different standard channels which can be differentiated by country code Channel Width it refers to maximum...

Page 34: ...d equivalent privacy WEP In client mode DH PFM88X searches for surrounding 5 8G wireless band provides basis for setting avoids interference source effectively and searches for those equipment with ac...

Page 35: ...rt is equivalent to a router LAN2 port of DH PFM88X is equivalent to LAN port of router whereas LAN port of POE power supplier is equivalent to WAN port of router In route mode connection diagram is s...

Page 36: ...of WAN port cannot be the same as existing IP in the network so as to prevent IP address conflict LAN IP IP address of LAN port to be set by the user according to needs However LAN IP shall not be the...

Page 37: ...mode is set to be Refuse and any one item in Mac1 Mac10 is set to be MAC address of the equipment to be filtered Except the equipment whose IP address is xxx xxx xxx xxx others are filtered Choose to...

Page 38: ...arameters according to this distance in order to optimize wireless connection quality Distance if Auto ACK Timeout Adjustment is enabled this distance setting becomes invalid the system will test devi...

Page 39: ...ecting speed and duplex mode of device on the other end LAN port automatically adjusts its speed to the highest public level so both ends of the line own the highest speed and duplex mode It is enable...

Page 40: ...and account information Figure 9 1 System Settings Figure 9 2 Accounts Information Backup Configuration click Download to backup present webpage configurations Note that configuration file contents ca...

Page 41: ...ttings click Reset on the webpage After a while device configurations are restored to factory settings Device Name the user can set the device name according to needs Login Timeout when login timeout...

Page 42: ...M88X ping result will be Alive otherwise it will be Not Alive Ping Watchdog it is used to monitor the operation of Wireless Bridge continuously In particular Ping tool is used when connecting remote h...

Page 43: ...of Syslog server and set server port to be 514 Then relevant log information will be seen on Syslog server NTP Client if DH PFM88X can go online NTP client function is enabled and URL of NTP server is...

Page 44: ...s bandwidth 300M coverage area 3km standard power supply high power antenna and dual feeder It applies to outdoor high temperature and low temperature environment 2 Wireless client DH PFM88 1 1 Outdoo...

Page 45: ...temperature and low temperature environment 2 Wireless client DH PFM881 1 Outdoor waterproof wide temperature 30 70 wireless bandwidth 300M coverage area 3km standard power supply It applies to outdoo...

Page 46: ...Outdoor waterproof wide temperature 30 70 wireless bandwidth 300M coverage area 3km standard power supply It applies to large construction site projects to be adjusted according to actual needs 3 Out...

Page 47: ...os No Type Model No Qty Description Feature 1 Wireless receiving end DH PFM88 0 4 IP66 wide temperature 30 70 wireless bandwidth 300M coverage area 3km standard power supply high power antenna and dua...

Page 48: ...1 Gigabit management switch 24 10 100 1000Base T 4 SFP Combo light natural heat dissipation without fan dustproof design It applies to non standard rural machine room Appendix Table 1 4 Recommended Mo...

Page 49: ...king rate and specific rate will depend on distance and environment To obtain maximum possible connecting rate the following links shall be tested 1 Position of wireless AP Try to adjust the position...

Page 50: ...It is suggested that the user should isolate their frequency and make sure that their channels don t overlap When channel width is 20M frequency difference between two devices shall be over 20M 7 Pack...

Page 51: ...realized at sea level and clear open land this is geographical condition used to evaluate communication distance of wireless communication equipment It is followed by semi clear and semi open environm...

Page 52: ...t at the maximum value 7 Try to Avoid Same Frequency Interference and Adjacent Frequency Interference When setting AP frequency employ the client to search what frequencies are being used by other equ...

Page 53: ...distance and wireless throughput rate with certain transmission distance Test No Occlusion This test was carried out at East China Sea Dike in Pudong New District of Shanghai the coastal dike has no o...

Page 54: ...ipment DH PFM880 DH PFM881 one DH PFM880 and one DH PFM881 were placed at both points respectively Test Result 1KM Test Result Equipment AP STA RSS dBm Throughput Mbps Channel Bandwidth 55 56 51 53 31...

Page 55: ...k 5500 MHz 20MHz 55 56 77 77 26 2 25 9 uplink and downlink 5785 MHz 40MHz 55 56 74 74 34 4 34 7 uplink and downlink 5500 MHz 40MHz 10KM Test Result Equipment AP STA RSS dBm Throughput Mbps Channel Ban...

Page 56: ...e as follows 1 Shenjiang Road is relatively straight but with ups and downs including bridges etc so it is slightly occluded environment 2 There are buildings many companies and hotels at both sides o...

Page 57: ...lt 2KM Test Result Equipment AP STA RSS dBm Throughput Mbps Channel Bandwidth 55 56 73 75 33 5 8 9 uplink and downlink 5785 MHz 20MHz 55 56 71 73 23 6 16 4 uplink and downlink 5500 MHz 20MHz 3 5KM Tes...

Page 58: ...49 Appendix Figure 4 6 Throughput and Distance Curve at Downtown Area and 20M bandwidth 40 37 5 42 4 28 1 2 3 5 5500MHz 5785MHz...

Page 59: ...rface POE Indicator light Wi Fi status indicator light LAN interface indicator light power indicator light signal strength indicator light Working temperature 30 70 Storage temperature 30 80 Working h...

Page 60: ...DAHUA VISION TECHNOLOGY CO LTD Address No 1199 Bin an Road Binjiang District Hangzhou P R China Postcode 310053 Tel 86 571 87688883 Fax 86 571 87688815 Email overseas dahuatech com Website www dahuas...