Local Configurations
173
Figure 5-168
Configure the triggering parameters. See Table 5-47.
Step 4
Parameter
Description
Period
Define a period during which the detection is active.
For details, see "Setting Motion Detection Period" section in
"5.10.4.1 Configuring Motion Detect Settings."
Alarm Out
Click
Setting
to display setting interface.
General Alarm: Enable general alarm and select the alarm
output port.
Ext. Alarm: Connect the alarm box to the Device and then
enable it.
Wireless Siren: Connect the wireless gateway to the Device
and then enable it. For details, see "5.12 IoT Function."
When an alarm event occurs, the system links the peripheral alarm
devices connected to the selected output port.
Latch
Set a length of time for the Device to delay turning off alarm after
the external alarm is cancelled. The value ranges from 0 seconds
to 300 seconds. If you enter 0, there will be no delay.
Show Message
Select the
Show Message
check box to enable a pop-up alarm
message in your local host PC.
Alarm Upload
Select the
Alarm Upload
check box to enable the system to
upload the alarm signal to the network (including alarm center)
when an alarm event occurs.
Not all models support this function.
The corresponding parameters in the alarm center should be
configured. For details, see "5.15.1.12 Configuring Alarm