3 Installation 

The Device supports rack mount. 
Step 1 

Attach the mounting bracket to the Device side panel (one on each side) and secure it with 
the screws provided with the rack. 

Figure 3-1 Install bracket 

 

Step 2 

Attach the Device to the rack with screws. 

Figure 3-2 Install device 

 

Summary of Contents for D-PFS4226-24ET-240

Page 1: ...PoE Switch 16 24 port Managed Desktop Switch Quick Start Guide V1 0 0 ...

Page 2: ...d due to operating the product in ways that are not in compliance with the manual The manual will be updated according to the latest laws and regulations of related jurisdictions For detailed information see the paper user s manual use our CD ROM scan the QR code or visit our official website The manual is for reference only Slight differences might be found between the electronic version and the ...

Page 3: ...II If there is any uncertainty or controversy we reserve the right of final explanation ...

Page 4: ...ctrical safety standards and make sure that the voltage in the area is steady and conforms to the power requirements of the device Do not connect the device to more than one power supply Otherwise the device might become damaged Observe all safety procedures and wear required protective equipment provided for your use while working at heights Do not expose the device to direct sunlight or heat sou...

Page 5: ...lames such as a lit candle on the device When installing the device make sure the power plug and appliance coupler are easy to reach to cut off the power Maintenance Requirements Power off the device before maintenance Mark key components on the maintenance circuit diagram with warning signs When replacing the battery make sure that the same type is used Improper battery use might result in explos...

Page 6: ... 2 2 1 Front Panel 2 2 2 Rear Panel 3 3 Installation 4 4 Wiring 5 4 1 Connecting GND 5 4 2 Connecting Power Cord 5 4 3 Connecting Ethernet Port 5 4 4 Connecting SFP Ethernet Port 6 4 5 Connecting PoE Ethernet Port 7 5 Quick Operation 8 5 1 Login through Web 8 5 2 Restoring to Factory Settings 8 Appendix 1 Cybersecurity Recommendations 9 ...

Page 7: ...web management SNMP and other functions the Device can be remotely managed It can directly connect to iLinksView The Device is applicable for use in different scenarios including homes offices small malls and on server farms 1 2 Features 16 24 100 Mbps PoE Ethernet ports uplink ports support gigabit optical ports or Ethernet ports All ports meet the requirements of IEEE802 3af and IEEE802 3at stan...

Page 8: ...utton Press and hold it for more than 5 seconds and release after the panel status indicators all turn on to restore the device to its default settings 4 Console port 5 PoE output power indicators Solid green Total power 50 Solid green and yellow 50 total power 80 Solid green yellow and red 80 total power 6 Single port connection status indicators Link On Connected to device Off Not connected to d...

Page 9: ...following figure is for reference only and might differ from the actual device Figure 2 2 Rear Panel Table 2 2 Description of the rear panel No Description 1 Power switch 2 Power port supports 100 240 VAC 3 Ground terminal ...

Page 10: ...ck mount Step 1 Attach the mounting bracket to the Device side panel one on each side and secure it with the screws provided with the rack Figure 3 1 Install bracket Step 2 Attach the Device to the rack with screws Figure 3 2 Install device ...

Page 11: ... 1 Connect GND 4 2 Connecting Power Cord Before connecting the power cord make sure that the Device is securely grounded Step 1 Connect one end of the power cord to the power jack of the Device Step 2 Connect the other end of the power cord to the external power socket 4 3 Connecting Ethernet Port The Ethernet port is a standard RJ 45 port With its self adaptation function it can be automatically ...

Page 12: ...static wrist band and confirm that the antistatic wrist band is in good contact with your skin and the Device is reliably grounded Step 2 Turn up the handle of the SFP optical module vertically and hold the optical module on both sides with your hands Step 3 Push the optical module gently into the slot in the horizontal direction until the SFP optical module is firmly connected to the slot Figure ...

Page 13: ...can directly connect this port to the Device PoE Ethernet port through the network cable to achieve synchronized network connection and power supply The maximum distance between the Device and the terminal device is about 100 m When connecting to a non PoE device the device needs to be used with an isolated power supply ...

Page 14: ... Web No initial password user defined during initialization iLinksView lt_91_il_02_nmp When using iLinksView for device management ensure that the username and password of the Device matches that of iLinksView otherwise iLinksView will not be able to discover the Device 5 2 Restoring to Factory Settings There are two ways to restore the Device to factory settings Press and hold the Reset button fo...

Page 15: ... suggest that you download and use the latest version of client software Nice to have recommendations to improve your equipment network security 1 Physical Protection We suggest that you perform physical protection to equipment especially storage devices For example place the equipment in a special computer room and cabinet and implement well done access control permission and key management to pr...

Page 16: ...der encrypted transmission will cause some loss in transmission efficiency 11 Secure Auditing Check online users we suggest that you check online users regularly to see if the device is logged in without authorization Check equipment log By viewing the logs you can know the IP addresses that were used to log in to your devices and their key operations 12 Network Log Due to the limited storage capa...

Reviews: