Dahua BF Series Installation Manual Download Page 17

    14 

which  is  used  for  temperature  correction  of  thermal  imaging  acquisition,  so  as  to  meet  the  accuracy 
requirements of 

±

  0.3 

Bold doesn't need to be connected to the camera, it's separate. After power on, it can be placed in the camera 
screen according to the installation instructions. 

2. Power on stabilization time of equipment. 

Blackbody: power on and preheat for 20 minutes; thermal imaging equipment: power on and preheat for 60 
minutes, with the best effect. 

3. Whether it can be installed in outdoor or semi outdoor environment. 

Because the outdoor temperature, wind, humidity and other environmental factors have a great impact on the 
temperature measurement of the thermal imaging surface, it is not recommended to be installed outdoors or 
in the area directly connected to the outdoor, but in a closed and relatively stable environment without wind. 

4. Why is it recommended to measure the temperature of frontal forehead? 

First of all, different people's forehead temperature also has temperature difference. In the case of mask, the 
exposed area of forehead is relatively large, which is more convenient for temperature measurement. 
The actual temperature of the front face and the side face of the same person / same position is different. With 
masks, the high temperature points are mainly in the forehead, ears and neck, and the temperature is different 
among different people. Therefore, it is required to face the camera and test the frontal temperature uniformly 
to reduce the impact of temperature difference between different parts. 

5. What is the best temperature range for temperature measurement? 

The best temperature range of indoor wind free and stable environment is 10 

  ~ 30 

 

6. The best distance for temperature measurement? 

The best temperature measurement distance is the same as the distance between blackbody and equipment. 
3.5mm detection distance is 2m, and the transverse width of 2m is about 1.5m; 7mm detection distance is 
3m, and the transverse width of 3m is about 1.3m; the temperature measurement value far from the optimal 
distance  will  be  reduced,  and  the  temperature  measurement  value  close  to  the  optimal  distance  will  be 
increased. 

7. How many heads can be tested? 

As shown in the figure below, in normal use, there are not many people (width 1.3-1.5m) at the best distance 
of temperature measurement. There is no limit to the number of heads in the detection area, but it is too far 
or there is overlap, which may result in missing or inaccurate temperature measurement. It is recommended 
to test one by one. 

 

8. Why does the image of thermal imaging channel get stuck after a period of time? Is it normal? 

Normal. In order to ensure image uniformity and temperature measurement accuracy, thermal imaging needs 
a period of time to set the blank back to zero for correction. During the process of setting the blank, the image 
will get stuck once, and the internal part of the equipment will "click" once, which is a normal situation. 

9. Why thermal imaging does not measure temperature after the first configuration 

The system time is not synchronized, refer to the time synchronization setting in system debugging. 

10. Why is the head frame inaccurate? 

It may be related to the installation angle and environmental background on site. If the head detection effect 
is not ideal, please provide the Dav video with two channels on site. Send Xu Fangrong and Fang Shengdong 
through Dahua interactive platform (select intranet Download for outgoing type). After receiving the video, 
the R & D will optimize and iterate according to the scene. 

Summary of Contents for BF Series

Page 1: ...Dahua Thermal Body Temperature Measurement Solution Installation Guide BF Series Zhejiang Dahua Technology Co Ltd...

Page 2: ...ture exceeds 35 there is a possibility of fever For other environmental temperature conditions it is recommended to measure several samples on site and increase 1 as the alarm threshold on the basis o...

Page 3: ...Preface II Change Record Revision date Version number Creater Reviser 2020 01 27 V1 0 2020 01 28 V1 1 2020 01 31 V1 2 2020 02 03 V1 3...

Page 4: ...2 General Settings 7 2 1 Equipment Upgrade 7 2 2 Debugging Of Human Body Temperature Detection Function 8 2 2 1 Selection of human body temperature measurement intelligent scheme 8 2 2 2 Blackbody Par...

Page 5: ...nd other requirements The PPT version of installation guidance video web operation guidance and guidance document should be obtained from the regional delivery supervisor In the future it will be sync...

Page 6: ...by one at the designated position BF5421 13mm installation requirements are consistent with BF3221 7mm 1 3 Installation Diagram BF3221 3 5mm installation diagram Blac kbod y Height 2m Side view h u m...

Page 7: ...objects 3m Height of Blackbody 1 8m Thermal camera focal length 13mm Blac kbod y Sidewalk width 1 5m Top view Thermal camera focal length 13mm 1 4 Scene Diagram BF3221 7mm as an example Distance betwe...

Page 8: ...Height of Blackbody 1 8m Personnel access direction 1 When the artificial diversion channel is lengthened as far as possible multiple S shaped can be used When the indoor and outdoor temperature diffe...

Page 9: ...e facing the camera irradiation direction the black body shall be on the left or right side of the thermal imaging picture and the tripod can be protected by temporary fence As follows blackbody is in...

Page 10: ...tified in the delivery group please pay attention to the group information in time The default to be restored after upgrading is as follows Note 1 If temperature compensation has been carried out in 2...

Page 11: ...blackbody one is the digital tube display right two the other is the LCD display left Note For the blackbody display of the LED just press the bottom to adjust the value for the LCD display device pr...

Page 12: ...fter drawing the wireframe should be drawn along the edge of the bright area before 20200210 the wireframe should be in the middle of the blackbody the smaller the wireframe the higher the measurement...

Page 13: ...in the figure below indicates that an audible and visual alarm will be generated when the head temperature of the subject exceeds 37 3 When the capture angle filter value is 1 only the front side simi...

Page 14: ...e Thermal Camera Face Frame Camera settings camera properties channel 2 find binocular calibration adjustment adjust the up down left and right arrows set step length according to the actual situation...

Page 15: ...12 3 Announcements The following is for blackbody Warning A warning indicates a condition that may cause harm to the user To avoid personal injury or instrument...

Page 16: ...iation strong electromagnetic interference and vibration Heat dissipation space shall be reserved around the blackbody and the distance from the surrounding objects shall not be less than 10cm Calibra...

Page 17: ...nt is 10 30 6 The best distance for temperature measurement The best temperature measurement distance is the same as the distance between blackbody and equipment 3 5mm detection distance is 2m and the...

Page 18: ...tion alarm Select event management blackbody exception alarm blackbody exception enable and turn on or off The default sensitivity is 60 and the lower the value the less likely it is to report blackbo...

Reviews: