Installation Guide 7
Figure 2-7
Figure 2-8
Table 2-2
Port
Wiring Terminal
Description
Lock control output
port
NC1
Lock control of door 1
COM1
NO1
NC2
Lock control of door 2
COM2
NO2
2.3.4 Wiring Description of Reader
1 door only supports to connect one type of reader—485 or Wiegand.
Please refer to Table 2-3 for descriptions of wiring terminals corresponding to readers. Take
door 1 for example; other readers are the same. Please refer to Table 2-4 for descriptions of
reader cable specification and length.
Table 2-3
Port
Wiring Terminal
Cable Color
Description
Entry Reader of
Door 1
485+
Purple
485 reader
485-
Yellow
LED
Brown
Wiegand reader
D0
Green
D1
White
CASE
Blue