Alarm Control Panel Installer Manual
110
8
Q: The configuration cannot be restored to the factory default setting.
A: The reason for this question is the parameter "FACTORY RST" is set to "NO" in the SYSTEM
FUNCTIONS menu, so the DIP reset does not work. In this case, please return the Control
Panel to the manufacturer.
9
Q: The battery cannot be charged, or it cannot be fully charged, or it is charged slowly.
A: Possible reasons as below.
The adapter that you use is not the original or the output voltage is not 14.5V DC.
The adapter hardware is damaged. Please disconnect the adapter from the Control
Panel, and then check whether the output voltage of the adapter is 14.5V DC.
The charging circuit of mainboard is damaged.
The battery is damaged.
10 Q: The Keypad has no response when pressing.
A: Possible reasons as below.
The main board is damaged.
Wrong connection between RS-485 wires and the Control Panel or the connection
becomes loose.
Keypad DIP address setting is wrong.
11 Q: During exit delay countdown, why does the detector generate alarms?
A: Possible reasons as below.
During exit delay countdown, if the protection zone with IMMEDIATE arming is
triggered, the detector generates alarms first and then resumes counting down if the
countdown was not ended.
During exit delay countdown, if the protection zone with DELAYED arming is triggered,
the detector exits from countdown first. After the arming is successful, if the protection
zone with DELAYED arming is triggered again, the enter countdown will start first, and
then generate alarms.
In conclusion, if you do not want the detector to generate alarms during exit delay
countdown, set the protection zone to be Delay or Path type.
ZHEJIANG DAHUA VISION TECHNOLOGY CO., LTD.
Address: No.1199, Bin'an Road, Binjiang District, Hangzhou, P.R. China
Postcode: 310053
Tel: +86-571-87688883
Fax: +86-571-87688815
Email: overseas@dahuatech.com
Website: www.dahuasecurity.com
Summary of Contents for ARC3008C
Page 1: ...Alarm Control Panel Installer Manual V1 0 1 ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD ...
Page 16: ...Alarm Control Panel Installer Manual 15 Wiring of detectors Figure 1 6 ...
Page 17: ...Alarm Control Panel Installer Manual 16 Keypad connection Figure 1 7 ...
Page 67: ...Alarm Control Panel Installer Manual 66 Vocal message flow Figure 1 36 ...