36
3-2) COLOR NOISE REDUCTION
• Adjustment Procedure
1. Preparation
1) Supply the Color bar signal to the VIDEO LINE IN JACK.
2) Supply 5V to PY05.
2. Adjustment
1) Set the VCR to the STOP(EE) Mode.
2) Set the Oscilloscope to the chop mode.
Connect CH1 to the V-OUT(RY09) and CH2 to the YNR TP (PY05) and trigger the scope with the signal from CH1.
3) Adjust RY91 until Color signal becomes minimum.
Location of Adjustment Parts
Observation Waveform
Y/C PCB
Horizontal Axis : 10
µ
S/DIV
Vertical Axis : 50 mV/DIV
Mode
Adjustment parts
Check point
Test equipment
Test tape
Input signal
EE
RY 91
PY09
Signal gen.
Color Bar
Oscilloscope
CH-2(PY09(NR)
Horizontal:10
µ
s/DIV
Vertical:50mv/DIV
Y/C PCB SOLDER SIDE
PY05
PY09
IY02
IY01
IY03
RY91
PAY02
PAY01