no problem

the time between two starting is shorter than 12min; or refrigerator room 
temperature is lower than the setting temperature, in this case, it is no 
problem. You need waiting more time.

Compressor wire not right or compressor 
damage

measure the voltage of compressor input connector, if it is OK then 
check the starting and relay of compressor, also check the wire if it is 
OK

6

product no any work

the PCB failure

check the power by multimeter,  if the input voltage is 220V-240, but the 
led, compressor, fan, defrost heater are all no work, it mean the PCB 
failure and need change a new PCB

PCB had automatic self-examination: open the cover of PCB at the back 
of product, plug in power and push the SW101 switch 3 seconds and the 
PCB begin automatic self-examination program, then the led and 
compressor and fan and defrost heater all work two second and then 
stop, all wore one time and then quit automatic self-examination 
program, and the program will return the original setting. If the 
automatic self-examination program no work, it mean the PCB failure 
and need change it

4

Compressor no starting

PCB failure