4. How To Charge R-600a Refrigerant
NO.
S VC process
Image
Details
1. Conect can adapter to the coupling pipe.
2. Charge the ref. with open lever slowly.
※
Refrigerant should never leak in the room.
1. On the power of refrigerator and then
start to charge the ref. (10min)
※
Charge the ref. until going out the water
vapour condensing on the can outlet.
1. Check the leakage.
※
You must rework from Step.1
when the leakage is detected.
1. Clean and clear around the machinery
14
Connecting of
coupling pipe
&
adapta
15
Charging
16
Leakage Test
room when the service is finished.
2. Assemble the machinery room cover.
17
Finish
30