9
4. TROUBLE SHOOTING GUIDE
TROUBLE
CAUSE
FILTER BAG(PAPER OR CLOTH)
IS FULL WITH DUST
SUCTION POWER
IS WEAK
CLOGGING OR TEAR IN HOSE
DEFECTIVE MOTOR
CHANGE IT WITH NEW ONE
OR REMOVE THE DUST
BREAKING IN POWER CORD
(AT BLADE TIP OR ROOT OF
PLUG)
CLEANER DOES
NOT WORK
REPLACE THE POWER
CORD (SEE 5-3)
DEFECTIVE SLIDE VOLUME
LOCATED IN COVER BODY
REPLACE IT (SEE 5-5)
DEFECTIVE PCB ASSEMBLY
REPLACE IT (SEE 5-5)
BREAKING OF CONNECTIONS
OR POOR CONTACTS IN CORD
REEL ASSEMBLY
REPAIR (SEE 5-3)
DEFECTIVE MOTOR
REPLACE IT (SEE 5-2)
BREAKING OF CONNECTIONS
IN COVER BODY ASSEMBLY
REPAIR (SEE 5-5)
DEFECTIVE SWITCH
REPLACE IT (SEE 5-5)
DEFECTIVE PCB ASSEMBLY
MOTOR DOES NOT
STOP EVEN IF
SWITCH
REPLACE IT (SEE 5-5)
REMOVE OBSCTACLE
OR REPLACE THE HOSE
REPLACE THE MOTOR
(SEE 5-2)
COUNTERMEASURE