Hardware Troubleshooting : Digital Board
-16-
1.3 In case of DTV mode
START
Select Air/Cable in Ant. Set correctly
Check the SMPS and input voltage
IC501 Problem.
Replace the Main PCB
Check the path from
TU101 to IC101
Check
1. The SNR is over 15dB
2. “Get 1SecSer” is “0”
The signal quality is poor.
1. Check the ANT or its connection is correct
2. Consult a local installer.
Perhaps Connector and Cable
Problem.
Replace the Main PCB
Check
the “Ant. Set” is correct
in Menu
Yes
No
Check
the LVDS connector and cable
is correct
Check
the LVDS signal output of IC501 is correct
(Pin A14, B14, A15, B15, A16, B16, A17,
B17, A18, B18, A19, B19)
Yes
No
No
Yes
Check
the input power of
IC501 is correct
No
No
Is “Lock status” “1(LOCK)”
when “Digital signal status” is
“on” in Service mode S10?
Yes
Check the path from IC301 to IC501
Yes
Does
digital signal input from IC301
to IC501
No
Check the path from IC301 to IC501
Yes
Does
TS signal input from IC101
to IC301
No
Yes
No
Summary of Contents for LCD TV
Page 13: ...5 Block Diagram 13 DLA 32 37 42LMBD BLOCK DIAGRAM...
Page 42: ...10 Schematics Digital Board 42...
Page 43: ...Schematics Digital Board 43...
Page 44: ...Schematics Digital Board 44...
Page 45: ...Schematics Digital Board 45...
Page 46: ...Schematics Digital Board 46...
Page 47: ...Schematics Digital Board 47...
Page 48: ...Schematics Digital Board 48...
Page 49: ...Schematics Digital Board 49...
Page 50: ...Schematics Digital Board 50...
Page 51: ...11 Schematics SMPS 51 1 FEL 3237A DLA 32 37C7LMBD...
Page 52: ...Schematics SMPS 52 2 FEL 42C2 DLA 42C7LMBD...
Page 53: ...12 Mechanical Development Figure 53 1 DLA 32C7LMBD...
Page 54: ...Mechanical Development Figure 54 2 DLA 37C7LMBD...
Page 55: ...Mechanical Development Figure 55 3 DLA 42C7LMBD...