Daewoo KOR-6L35 Service Manual Download Page 4

17

(TROUBLE 1) Oven does not operate at all ; any inputs can not be accepted.

TROUBLESHOOTING GUIDE 

Following the procedure below to check if the oven is defective or not.

1. Check grounding before trouble checking.
2. Be careful of the high voltage circuit.
3. Discharge the high voltage capacitor.
4. When checking the continuity of the switches, fuse or high voltage transformer, disconnect one lead wire from these parts

and check continuity with the AC plug removed. To do otherwise may result in a false reading or damage to your meter.

Does the
fuse blow?

NO

NO

NO

Does the fan motor work when you 
shut the door and turn the timer?

YES

If outlet has proper voltage, check 
continuity of power supply cord.

Replace power supply cord.

NO Continuity

Check continuity of interlock
monitor switch with door shut.

Replace primary, secondary interlock 
switch and interlock monitor switch.

Continuity

Both continuity

Replace fuse and check 
continuity of both interlock
switch's contact and monitor
switch's contact with door
partially open until monitor
switch contact.

Replace primary, secondary interlock 
switch and interlock monitor switch.

NO

Fuse again

Disconnect one side of the 
lead wire connected from 
transformer to the high 
voltage capacitor, and operate 
oven.

Replace high voltage capacitor.

Replace high voltage transformer

Normal

(NOTE1)

(NOTE1)

NOTE1 : All these switches must be replaced at the same time, please refer to “Interlock Mechanism And

Adjustment”

Summary of Contents for KOR-6L35

Page 1: ...3S001 May 2010 Caution In this Manual some parts can be changed for improving their performance without notice in the parts list So if you need the latest parts information please refer to PPL Parts P...

Page 2: ...0 W MICROWAVE ENERGY OUTPUT 700 W FREQUENCY 2 450MHz OUTSIDE DIMENSIONS W H D 446 x 270 x 319 mm CAVITY DIMENSIONS W H D 295 x 219 x 303 mm CAVITY VOLUME 20 L NET WEIGHT APPROX 10 6 Kg TIMER 35min DUA...

Page 3: ...4 1 OUTER DIMENSION 446 319 270 EXTERNAL VIEW...

Page 4: ...mer YES If outlet has proper voltage check continuity of power supply cord Replace power supply cord NO Continuity Check continuity of interlock monitor switch with door shut Replace primary secondary...

Page 5: ...able motor NO If microwave do not oscillate check continuity of filament of magnetron Poor continuity NO Continuity Check continuity filament tap 3 3V of high voltage Replace high Voltage transformer...

Page 6: ...r the water temperature to attain 20 C 2 C is measured The oven is then switched off and the final water temperature is measured within 60s NOTE 1 The water stirred is before its temperature is measur...

Page 7: ...binet door seem door viewing screen the exhaust air vents and the suction air vents 3 Measuring should be in a counter clockwise direction at a rate of 1 in sec If the leakage of the cabinet door seem...

Page 8: ...reading Meter with 6V 9V or higher voltage batteries should be used to check the front back resistance of the diode otherwise an infinite resistance may be read in both directions A normal diode s res...

Page 9: ...22 WIRING DIAGRAM...

Page 10: ...OR ASSEMBLY Refer to Disassembly and assembly 2 CONTROL PANEL ASSEMBLY Refer to Disassembly and assembly 3 GUIDE WIND ASSEMBLY Refer to Disassembly and assembly 4 TOTAL ASSEMBLY EXPLODED VIEW AND PART...

Page 11: ...00 DIODE HV AS HVR 1X 30B 187 1 F21 3518701100 FUSE HV 5KV 0 55A HV 41A55 02 1 F22 3518122950 TRANS HV R1S57A DA30 1 F23 3516003700 SPECIAL SCREW TT3 HEX 4X8 FLG MFZN 4 F24 3510317500 BASE SBHG T0 5 1...

Page 12: ...S M NO OR6L353S001 DAEWOO ELECTRONICS CORP 1 2 Jeo dong 1 il ga Jung gu Seoul Korea C P O BOX 8003 SEOUL KOREA TELEX DWELEC K28177 8 CABLE DAEWOOELEC PRINTED DATE May 2010...

Reviews: