1. To remove cabinet  

1) Remove three screws on cabinet back.
2) Push the cabinet backward.

2. To remove door assembly

1) Remove two screws which secure the stopper hinge top.
2) Remove the door assembly from top plate of cavity.
3) Reverse the above for reassembly.

NOTE  : After replacing the door assembly, perform a check of

correct alignment with the hinge and cavity front plate.

9

Summary of Contents for KOR-6C075S

Page 1: ...C075S001 http svc dwe co kr Feb 2003 Caution In this Manual some parts can be changed for improving their performance without notice in the parts list So if you need the latest parts information pleas...

Page 2: ...y defective or misadjusted components in the interlock monitor door seal and microwave generation and transmission systems shall be repaired replaced or adjusted by procedures described in this manual...

Page 3: ...oven unit is found to servicing a microwave emission check should be performed prior to servicing the oven a inform the manufacturer importer or assembler b repair the unit at no cost to the owner c a...

Page 4: ...ICROWAVE FREQUENCY 2450MHz OUTSIDE DIMENSIONS 465 x 279 x 365 mm 18 3 x 11 0 x 14 4 in CAVITY DIMENSIONS 290 x 220 x 306 mm 11 4 x 8 7 x 12 0 in NET WEIGHT APPROX 12 7kg 27 9 Ibs TIMER 35 MIN DUAL SPE...

Page 5: ...EXTERNAL VIEW 1 OUTER DIMENSION 465 365 279 4...

Page 6: ...AL Door seal maintains the microwave within the oven cavity and prevents microwave leakage 6 GLASS COOKING TRAY Made of special heat resistant glass Food in a proper receptacle is placed on this tray...

Page 7: ...ith cable of same type Such a cable can be purchased from DAEWOO and must be installed by a qualified person 6 Examine the oven after unpacking for any damage such as A misaligned door broken door or...

Page 8: ...the desired time 7 When the timer reaches zero a bell will ring and the unit will turn off Oven light turns off If additional cooking time is needed and the door is closed the oven will automatically...

Page 9: ...work 2 Warning about the electric charge in the high voltage capacitor For about 30 seconds after the operation stopped and electric charge remains in the high voltage capacitor When replacing or che...

Page 10: ...2 To remove door assembly 1 Remove two screws which secure the stopper hinge top 2 Remove the door assembly from top plate of cavity 3 Reverse the above for reassembly NOTE After replacing the door a...

Page 11: ...12206400 FRAME DOOR HIPS 1 A02 3517007300 BARRIER SCREEN 0 PET T0 125 1 A03 3515204100 STOPPER SINGE T AS KOR 63150S 1 A04 3511719600 DOOR WELD AS KOR 6C0B5S 1 A05 3517002800 BARRIER SCREEN I T0 1 1 A...

Page 12: ...top and then push the door to contact the door seal to oven front surface Tighten two screws 2 To reduce gap located on part B Loosen two screws on stopper hinge under and then push the door to contac...

Page 13: ...eassembly REF NO PART CODE PART NAME DESCRIPTION Q TY REMARK B01 3513407210 KNOB VPC HIPS 1 B02 3516729010 CONTROL PANEL HIPS 1 B03 3515101600 SPRING FLAT SUS 301 T0 5 1 B04 3517402110 COUPLER VPC KNO...

Page 14: ...emove a screw which secure the magnetron 2 Remove the magnetron 3 Reverse the above steps for reassembly NOTE Never install the magnetron without the metallic gasket plate which is packed with each ma...

Page 15: ...e wind guide assembly 1 Remove a screw for earthing 2 Remove the noise filter from the wind guide 3 Remove a screw which secure the wind guide assembly 4 Draw forward the wind guide assembly 5 Pull th...

Page 16: ...shes the lock lever downward The lock lever presses the button of the interlock monitor switch to bring it under NO condition and presses the button of the secondary interlock switch to bring it under...

Page 17: ...or work when you shut the door and turn the timer YES If outlet has proper voltage check continuity of power supply cord Replace power supply cord NO Continuity Check continuity of interlock monitor s...

Page 18: ...e motor NO If microwave do not oscillate check continuity of filament of magnetron Poor continuity NO Continuity Check continuity filament tap 3 3V of high voltage Replace high Voltage transformer No...

Page 19: ...l the load is immediately placed on the center of the shelf which is in the lowest normal position 4 Microwave power is switched on 5 Heating time should be exactly A seconds Refer to table as followi...

Page 20: ...binet door seem door viewing screen the exhaust air vents and the suction air vents 3 Measuring should be in a counter clockwise direction at a rate of 1 in sec If the leakage of the cabinet door seem...

Page 21: ...set on the highest resistance scale measure the resistance across the diode terminals Reverse the meter leads and again observe the resistance reading Meter with 6V 9V or higher voltage batteries shou...

Page 22: ...WIRING DIAGRAM 21...

Page 23: ...22 EXPLODED VIEW AND PARTS LIST 1 DOOR ASSEMBLY Refer to Disassembly and assembly 2 CONTROL PANEL ASSEMBLY Refer to Disassembly and assembly 3 TOTAL ASSEMBLY...

Page 24: ...HV 5KV 0 55A HV 41A55 02 1 F25 3518117210 TRANS HV DW R80S0 63T A 1 F26 3516003700 SPECIAL SCREW TT3 HEX 4X8 FLG MFZN 4 F27 3510311700 BASE SBHG T0 7 1 F28 7112401011 SCREW TAPPING T1 TRS 4 10 MFZN 5...

Page 25: ...S M NO R6C075S001 DAEWOO ELECTRONICS CORP 686 AHYEON DONG MAPO GU SEOUL KOREA C P O BOX 8003 SEOUL KOREA TELEX DWELEC K28177 8 CABLE DAEWOOELEC PRINTED DATE Feb 2003...