18
8. To remove fannotor assembly.
(1) Remove screw
¤
from the rear panel of cavity.
(2) Remove screw
¤
from the rear panel of cavity.
(3) Pull out the guide wind assembly.
(4) Pull out the fan
¤º
from the fan motor
¤Ø
.
(5) Remove two screws
¤Ł
from the fan motor
¤Ø
.
(6) Remove the fan motor
¤Ø
out of guide wind
¤Œ
.
(7) Remove the filter
¤
out of guide wind
¤Œ
.
(8) Reverse the above steps for reassemble.
9. To remove transformer.
(1) Remove the four screw
¤
holding the H.V.
transformer
¤Ł
.
(2) Remove the transformer
¤Ł
.
(3) Reverse the above steps for reassembly.
CAUTION : Never install the magnetron without the metallic gasket plate which is packed with each magnetron
to prevent microwave leakage. Whenever repair work is carried out on magnetron, check the
microwave leakage. It shall nor exceed 4mW/cm2 for a fully assembled oven with door normally
closed.
2
1
Metallc Gasket Plate
Magnetron Antenna
Wave Guide
Magnetron
antenna
Metallic
gasket
plate
Cooling fin
Magnetron
Filament
terminal
5
4
6
3
2
7
1