30
(TROUBLE 3) No microwave oscillation even though fan motor rotates.
CONDITION
CHECK
RESULT
Check continuity of high
voltage capacitor terminals
with wires removed
Continuity
CAUSE
Defective high
voltage
transformer
REMEDY
Replace
No
microwave
oscillation
Check continuity of high voltage
rectifier in forward and backward
direction with DC megger
Continuity in
backward
direction
Defective high
voltage rectifier
Replace
Connect megger leads to
magnetron terminal and
magnetron body
Continuity
Defective
magnetron
Replace
Check resistance of primary and
secondary coil of high voltage
transformer
0
Ω
or infinity
Defective high
voltage
transformer
Replace
Check continuity of magnetron
with wires removed
No
Continuity
Defective
magnetron
Replace
Check continuity of filament
terminal of high voltage
transformer
No
Continuity
Defective high
voltage
transformer
Replace
Check D.C. voltage being
supplied to RELAY (RY1) coil
0 V
Defective touch
control circuit
Replace
Approx
15 VDC
Faulty
contacts or
RELAY (RY1)
or open
relay coil
Replace
Summary of Contents for KOR-1A0A0A
Page 7: ...6 3 EXTERNAL VIEW 1 OUTER DIMENSION 1 KOR 1A0A 1A1G H 2 KOR 1A4G H...
Page 8: ...7 3 KOR 1A7G 4 KOR 1A8Q...
Page 9: ...8 5 KOR 1A9H...
Page 36: ...35 10 WIRING DIAGRAM 1 KOR 1A1G H 9A27 1A7G9A27 1A9H9A27 1A1H9A37 1A4H9A27...
Page 37: ...36 2 KOR 1A0A0A 1A1G H 0A 1A4G H 0A 1A8Q0A 1A9H9A...
Page 39: ...38 Measure Point...
Page 41: ...40 2 PCB CIRCUIT DIAGRAM...
Page 44: ...43 Measure Point MP1 MP2...
Page 46: ...45 2 PCB CIRCUIT DIAGRAM...