1) Transistor(NPN Type)
2) Diode and zener diode
52
51
Emitter
Collector
Q1 ~ Q12
Base
DIODE Cathode (K) ANODE (A) D1-15
ZENER DIODE Cathode (K) ANODE (A) ZD1-6
6) When the door is opened during operation, the count down timer does not stop.
CHECK METHOD
7) When the digital clock does not oeprate properly.
If clock does not keep exact time, you must check Diode D6, transistor Q2.
BL
BL
CN1
EARTH
TERMINAL
D.O.M
S/W
A
1
2
3
-5V
R10
C8
R11
B
-5V
40
MICOM
4
5
D12
D13
D10
D11
C15
D15
R1
R2
R9
Q2
C9
44
-5V
C7
A
B
C
MICOM
POINT
A
B
STAGE
1) DOOR OPENED
OPEN
-5VDC
2) DOOR CLOSED
CLOSED
GND
CHECK NO.
METHOD
REMEDY
1
Check the state (ON,OFF) of the secondary
Replace secondary
Interlock switch by resistance measurement.
interlock switch
POINT
WAVEFORM
A
B
C
+5V
0V
T
T: 20 ms (50Hz)