15
8. To remove wind guide assembly.
1) Remove a screw for earthing.
2) Remove the noise filter from the wind guide.
3) Remove a screw which secure the wind guide assembly.
4) Draw forward the wind guide assembly.
5) Pull the fan from the motor shaft.
6) Remove two screws which secure the motor shaded pole.
7) Remove the motor shaded pole.
8) Reverse the above steps for reassembly.
9. To remove H.V.transformer.
1) Remove four screws holding the H.V.transformer.
2) Remove the H.V.transformer.
3) Reverse the above steps for reassembly.
Summary of Contents for KOG-6CDB5S
Page 5: ...4 EXTERNAL VIEW 1 OUTER DIMENSION 465 354 279...
Page 27: ...26 WIRING DIAGRAM...
Page 29: ...28 Measure Point MP1 MP2...
Page 31: ...30 2 PCB CIRCUIT DIAGRAM...