3. When there is no microwave oscillation
1) When touching
START
pad, oven lamp does not turn on.
Fan motor do not rotate, but cook indicator in display comes on.
Cause :
RELAY 2
does not operate.
refer to Circuit Diagram (point 3)
- Check method
2) When touching
START
pad, oven lamp turns on.
Fan motor and turntable rotate and cook indicator in display comes on.
Cause :
RELAY 1
does not operate.
refer to Circuit Diagram (point 2)
- Check method
4. When there is no grill oscillation.
Cause : RELAY 3 does not operate.
refer to Circuit Diagram (point 6)
- Check method
5. When the door is opened during operation, the count down timer does not stop.
refer to Circuit Diagram (point 1)
- Check method
6. When the digital clock does not operate properly.
refer to Circuit Diagram (point 5)
29
POINT
A
B
STATE
RELAY 2
ON
5VDC
GND
RELAY 2
OFF
GND
12VDC
POINT
A
B
STATE
RELAY 1
ON
5VDC
GND
RELAY 1
OFF
GND
12VDC
POINT
A
B
STATE
RELAY 3 ON
5VDC
GND
RELAY 3 OFF
GND
12VDC
POINT
A
B
STATE
1) DOOR OPEN
OPEN
5VDC
2) DOOR CLOSED
CLOSE
GND
CHECK NO
METHOD
REMEDY
1
Check the stage(ON, OFF) of the door open monitor
Replace door open monitor switch.
switch by resistance measurement.
POINT
WAVE FORM
A
3. When there is no microwave oscillation
1) When touching
START
pad, oven lamp does not turn on.
Fan motor do not rotate, but cook indicator in display comes on.
Cause :
RELAY 2
does not operate.
refer to Circuit Diagram (point 3)
- Check method
2) When touching
START
pad, oven lamp turns on.
Fan motor and turntable rotate and cook indicator in display comes on.
Cause :
RELAY 1
does not operate.
refer to Circuit Diagram (point 2)
- Check method
4. When there is no grill oscillation.
Cause : RELAY 3 does not operate.
refer to Circuit Diagram (point 6)
- Check method
5. When the door is opened during operation, the count down timer does not stop.
refer to Circuit Diagram (point 1)
- Check method
6. When the digital clock does not operate properly.
refer to Circuit Diagram (point 5)
29
POINT
A
B
STATE
RELAY 2
ON
5VDC
GND
RELAY 2
OFF
GND
12VDC
POINT
A
B
STATE
RELAY 1
ON
5VDC
GND
RELAY 1
OFF
GND
12VDC
POINT
A
B
STATE
RELAY 3 ON
5VDC
GND
RELAY 3 OFF
GND
12VDC
POINT
A
B
STATE
1) DOOR OPEN
OPEN
5VDC
2) DOOR CLOSED
CLOSE
GND
CHECK NO
METHOD
REMEDY
1
Check the stage(ON, OFF) of the door open monitor
Replace door open monitor switch.
switch by resistance measurement.
POINT
WAVE FORM
A
3. When there is no microwave oscillation
1) When touching
START
pad, oven lamp does not turn on.
Fan motor do not rotate, but cook indicator in display comes on.
Cause :
RELAY 2
does not operate.
refer to Circuit Diagram (point 3)
- Check method
2) When touching
START
pad, oven lamp turns on.
Fan motor and turntable rotate and cook indicator in display comes on.
Cause :
RELAY 1
does not operate.
refer to Circuit Diagram (point 2)
- Check method
4. When there is no grill oscillation.
Cause : RELAY 3 does not operate.
refer to Circuit Diagram (point 6)
- Check method
5. When the door is opened during operation, the count down timer does not stop.
refer to Circuit Diagram (point 1)
- Check method
6. When the digital clock does not operate properly.
refer to Circuit Diagram (point 5)
29
POINT
A
B
STATE
RELAY 2
ON
5VDC
GND
RELAY 2
OFF
GND
12VDC
POINT
A
B
STATE
RELAY 1
ON
5VDC
GND
RELAY 1
OFF
GND
12VDC
POINT
A
B
STATE
RELAY 3 ON
5VDC
GND
RELAY 3 OFF
GND
12VDC
POINT
A
B
STATE
1) DOOR OPEN
OPEN
5VDC
2) DOOR CLOSED
CLOSE
GND
CHECK NO
METHOD
REMEDY
1
Check the stage(ON, OFF) of the door open monitor
Replace door open monitor switch.
switch by resistance measurement.
POINT
WAVE FORM
A
3. When there is no microwave oscillation
1) When touching
START
pad, oven lamp does not turn on.
Fan motor do not rotate, but cook indicator in display comes on.
Cause :
RELAY 2
does not operate.
refer to Circuit Diagram (point 3)
- Check method
2) When touching
START
pad, oven lamp turns on.
Fan motor and turntable rotate and cook indicator in display comes on.
Cause :
RELAY 1
does not operate.
refer to Circuit Diagram (point 2)
- Check method
4. When there is no grill oscillation.
Cause : RELAY 3 does not operate.
refer to Circuit Diagram (point 6)
- Check method
5. When the door is opened during operation, the count down timer does not stop.
refer to Circuit Diagram (point 1)
- Check method
6. When the digital clock does not operate properly.
refer to Circuit Diagram (point 5)
29
POINT
A
B
STATE
RELAY 2
ON
5VDC
GND
RELAY 2
OFF
GND
12VDC
POINT
A
B
STATE
RELAY 1
ON
5VDC
GND
RELAY 1
OFF
GND
12VDC
POINT
A
B
STATE
RELAY 3 ON
5VDC
GND
RELAY 3 OFF
GND
12VDC
POINT
A
B
STATE
1) DOOR OPEN
OPEN
5VDC
2) DOOR CLOSED
CLOSE
GND
CHECK NO
METHOD
REMEDY
1
Check the stage(ON, OFF) of the door open monitor
Replace door open monitor switch.
switch by resistance measurement.
POINT
WAVE FORM
A
T: 20 ms(50Hz)
If clock does not keep
exact time, you must
check C6, D7, R19, R20,
ZD2.
0