Safety Cut
– Out
Warning:
This appliance is fitted with a built in safety cut-out, if the cut-
out is activated the unit stops working, unplug the heater from the mains and
check that the air intake area is not blocked or covered.
Leave for an hour to cool and reset before plugging back into the mains.
Electrical Connections
This appliance is fitted with a fused three-pin plug to BS 1363. If the plug has
to be removed, it should be cut off and carefully disposed of immediately. To
avoid a possible shock hazard, do not insert the discarded plug into a mains
socket.
Fitting a new plug
The mains lead must be connected as shown below. The wires are coloured with
the following code -
Brown wire = Live (L), Blue wire = Neutral (N).
NB
no
connection must be made to the Earth (E) terminal.
The Blue wire must be connected to the terminal marked N or coloured Black.
The Brown wire must be connected to the terminal marked L or coloured Red.
The Green and Yellow wire must be connected to the terminal marked E or coloured
Green.
Check that there are no cut or stray strands of wire inside the plug.
Use a 13 Amp BS 1362 fuse, only use BSI or ASTA approved fuses.
If you are in any way unsure which plug or fuse to use, always refer to a qualified
electrician.
After replacing or changing a fuse on a moulded plug, the cover must be refitted to
the plug; the appliance must not be used without a fuse cover.
WARNING: Do not wrap the cord around the heater for storage.
Connect
Brown to
Live (L)
Connect
Blue to
Neutral (N)
Ensure the outer sheath of the mains
lead is securely held by the cable clamp