2. Normal Defrost Mode
FUNCTIONS ( Defrost Mode )
PRECOOL
HEATER
DEFROTING
PAUSE
FAN DELAY
1) PRECOOL
- Compressor runs ( to cool down the freezer compartment prior to heater switch on )
for 50minutes or until Freezer sensor temperature reaches -27C
2) HEATER DEFROSTING
- Defrost heater is switch on until Defrost Sensor temperature reaches 13C.
- Heater operation time
; 30 seconds - Heater is ON free of Defrost Sensor.
; 30 minutes - When Defrost Sensor is malfunction. ( D1 error )
; 80 minutes - Heater maximum operation time. ( F3 error )
3) PAUSE
- After Defrost Heater switch OFF, Compressor dosen't run within 7 minutes.
4) FAN DELAY
- Freezer & Refrigerator fan switch on after 5miunuts' cmopressor running.
3. Forced Defrost Mode
1) How to start
( Basic Models Only )
; Press the REF. SET button 5 times while pushing the FRZ. SET button.
( Dispenser Models Only )
- Press the LOCK button.
- Press the Refrigerator Set button 5 times while pushing the Freezer Set button.
2) Except PRECOOL, steps are same as above
2. Normal Defrost Mode
.
Normal Mode
PRECOOL
Defrsot Heater
Time
Division
Compressor
Freezer Fan
Refrigerator Fan
50min
ON
Off
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
7min
OFF
PAUSE
HEATER DEFROST
FAN DELAY
Control
30min ( D1 error )
80min ( F3 error)
ON
5min
12
Summary of Contents for FRS-U20IV
Page 3: ...2 External Size SPECIFICATIONS 2...
Page 29: ...1 Inner Basic Model 2 Basic Model WIRING DIAGRAM Refrigerant R 134a Type 3 Dispenser Model 28...
Page 30: ...1 Inner Basic Model 2 Basic Model WIRING DIAGRAM Refrigerant R 600a Type 3 Dispenser Model 29...
Page 52: ...COOLING CYCLE HEAVY REPAIR Brzing Reference Drawings 51...
Page 54: ...How to install water line Dispenser models only 53...
Page 55: ...How to install water line Dispenser models only 54...