21. Regulation of R-sensor OFF Point
22. Summary of Function
CONTENTS
How to start function modes
All the modes are started with "LOCK ON".
A/S forced defrosting
"FRZ SET." + "REF SET." 5 times.
"FRZ SET." + "SUPER FRZ." 5 times.
"FRZ SET." + "REF SET." + "SLEEP" 5 times.
Pull down Functions
Explanation after delivery &
installation
"REF SET." for 3 sec. Right after first power
in.
ERROR display
"SLEEP" + "LOCK" 5 times.
EERROM Clear
"ICE MAKER LOCK" for 3 sec.
Reset water filter
"REF SET." + "SLEEP" 5 times.
DEMO function
INPUT
Control Object
Resistance of R-sensor Mid ON/OFF Point
CONTENTS
REMARKS
Regulation of R-sensor OFF point (1.5degree DOWN)
In case refrigeration of refrigerator is weak or insufficient, take the following action.
R-
SENSOR
R36
R37
R38
R36 : R-SENSOR standard resistance in normal mode (31.4K )
R37 : In case of weak ref., cut J1 to down the standard resistance by 1.5deg(2K)
R38 : In case of weak ref., cut J2 to down the standard resistance by 1.5deg(2K)
R36 = Mid ON/OFF point
R36 + R37 = Mid OFF point - 1.5 deg
R36 + R37 + R38 = Mid OFF point - 3.0 deg
J1, J2 on Main PCB