16
1. How to start
- Push the ‘LOCK’ button.
- Push the ‘LOCK’ button 10 times while pushing ‘REF.SET’ button.
2. How to control : Compressor, Freezer/Refrigerator/Compressor-Fan are ON continuously.
3. Display : ‘Co’ display in Error Mode. ( See ‘Error Mode for detail )
4. How to stop ; Plug out or after 30 hours.
INPUT
CONTROL OBJECT
CONTENTS
Front PCB
Electrical Devices
4-8. Pull Down Mode
; For 6 minutes after compressor OFF, it doesn’t operate even though Freezer sensor is ON.
INPUT
CONTROL OBJECT
CONTENTS
None
Compressor
4-9. Prevention of Compressor Restart
Buzzer rings;
1. If pressing the front display button
2. If initial plug in.
3. Compulsory operation ( Pull Down Mode )
4. If doors opening. ( Buzzer rings in the interval 1 min for 5 min. )
5. When pushing the button to adjust sensor ON/OFF point.
INPUT
CONTROL OBJECT
CONTENTS
F-PCB button
Door Switch
Initial Power Input
Buzzer
4-10. Alarm Function