24
OPERATION AND FUCTIONS
CONTENTS
REMARKS
3. Flow Chart of Defrosting Start
Start
Ambient temp. is over 35
?
Comp. work time is over 10 hours ?
Total time is over 60 hours ?
Comp. work time is over 6 hours ?
Any error ?
Comp. work rate is over 65 % ?
End
Defrosting mode starts.
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
Comp. work time is over 2 hours ?
Total door open time is over 3
minutes ?
Yes
Yes
No
No
Comp. work time is over 8 hours ?
No
No