73
1) Nitrogen only should be used when cleaning inside of cycle pipes
inside and sealing.
2) Check leakage with an electronic leakage tester.
3) Be sure to use a pipe cutter when cutting pipes.
4) Be careful not the water let intrude into the inside of the cycle.
Others.
1) Weld under nitrogen atmosphere in order to prevent oxidation
inside a pipe. (Nitrogen pressure : 0.1~0.2 kg/cm2.)
Nitrogen blowing
welding.
1) Be sure to replace drier when repairing pipes
and injecting refrigerant.
Replacement of drier.
1) Remove retained refrigerant more than 5 minutes after turning off
a refrigerator. (If not, oil will leak inside.)
2) Remove retained refrigerant by cutting first high pressure side
(drier part) with a nipper and then cut low pressure side.
(If the order is not observed, oil leak will happen.)
Removal of retained
refrigerant.
1) Use special parts and tools for R-134a or R-600a
Use of tools.
Precautions
Items
10-2. Precautions During Heavy Repair
Process tube
Compressor
Evaporator
Dryer
High Pressure side
Low pressure
side
Suction tube
Discharge tube
Condenser
Hot Pipe
Summary of Contents for FRN-U20IB series
Page 4: ...3 2 1 External Size 2 EXTERNAL VIEWS FRS N U20IB Downloaded from Fridge Manual com Manuals...
Page 5: ...4 FRS N U20DB EB Downloaded from Fridge Manual com Manuals...
Page 6: ...5 FRS N U20FB GB Downloaded from Fridge Manual com Manuals...
Page 38: ...37 6 1 Wiring Diagram 6 DIAGRAM Basic Model Downloaded from Fridge Manual com Manuals...
Page 39: ...38 Dispenser Model Downloaded from Fridge Manual com Manuals...
Page 40: ...39 6 2 Circuit Diagram of Main PCB Basic Model Downloaded from Fridge Manual com Manuals...
Page 41: ...40 Downloaded from Fridge Manual com Manuals...
Page 42: ...41 Dispenser Model Downloaded from Fridge Manual com Manuals...
Page 43: ...42 Downloaded from Fridge Manual com Manuals...
Page 85: ...84 11 5 Dispenser Water Flow Downloaded from Fridge Manual com Manuals...