 2. Refrigerator Compartment Control

 1) Adjust by the pushing the REF.SET button.

 2) Refrigerator Compartment ON/OFF Difference 

    - Dial 5C / 4C / 3C : 2.0C

    - Dial 2C : 2.1C

    - Dial 1C : 2.6C

    - Dial 0C : 3.5C

    * Medium OFF point : 3.5C

 3) Quick Refrigerator Mode : This mode runs for 40 minutes.

Functions

Plug in

1st Press

2nd Press

3rd Press

4th Press

5th Press

6th Press

On

5.6

4.6

4.5

1.5

9.6

8.6

6.6

Off

3.5

2.0

1.0

-2.0

7.6

6.6

4.6

Medium

Max

Max

Quick

Sensor

Min - Medium

Min

1

0

0*

5

4

3

Division

Display

2

Mode

Medium

  - This mode runs for 40 min until the sensor reach -2.0 C and free of Freezer sensor.

  - After this mode, the dial setting is to Medium.

  - In this mode defrosting is not active. Defrosting is priority to Quick mode.

Refrigerator
Sensor

Refrigeration
OFF point

Normal 
Control

NORMAL MODE

QUICK MODE (40MIN )

9

Summary of Contents for FRN-T30H3GP

Page 1: ...FRN T30H3GP FRT 803ZG FRN T30H3TB FRT 803HB FRN T30H3PW FRT 813HP FRN T30H2MW FRT 822HW May 2013...

Page 2: ...78 6 530 0 374 2 150W 893 1790 141 kg 893 954 149 kg DREP 9020 LR 893 954 Compulsory Convection Type 954 R 600a 70g Fin Type 149 kg 140 kg 210W 954 Diemension DC 12V AC 250V 10A 77C DREP 9020 LR DRCP...

Page 3: ...Specification 2 Outside Diemension 2...

Page 4: ...1 Door storage compartment 7 Egg case 2 Ice maker Ice storage bin 8 Door storage compartment 3 Freezer shelf 9 Can pocket 4 Freezer compartment drawer 10 Multi crisper 5 Takeout case 11 Vegetable fru...

Page 5: ...rage compartment 6 Egg case 2 Ice maker Ice storage bin 7 Door storage compartment 3 Freezer shelf 8 Can pocket 4 Freezer compartment drawer 9 EZ Home bar 5 Refrigerator shelf 10 Vegetable fruit drawe...

Page 6: ...Refrigerant Cycle 5...

Page 7: ...Air Flow Side View Freezer Compartmnet Refrigerator Compartmnet The illustration is FRN T30H3GP FRN T30H3TB model 6...

Page 8: ...u press the Ref Set button the setting temperature changes below order d Lock button Childproof lock 1 After 2 minutes when no dial setting this mode is active automatically Except Lock icon all Led i...

Page 9: ...erature Point in Each Mode Functions Plug in 1st Press 2nd Press 3rd Press 4th Press 5th Press 6th Press 7th Press 8th Press Division 5 Quick Freezer Mode In this mode Compressor Freezer Fan motor is...

Page 10: ...d Press 3rd Press 4th Press 5th Press 6th Press On 5 6 4 6 4 5 1 5 9 6 8 6 6 6 Off 3 5 2 0 1 0 2 0 7 6 6 6 4 6 Medium Max Max Quick Sensor Min Medium Min 1 0 0 5 4 3 Division Display 2 Mode Medium Thi...

Page 11: ...r li Remark 4 5 C same as Ref compartment 2 5 C Off 1 0 C Speed 4 5 C Division Fish Meat Vegetable On 1 0 C 2 5 C 2 Load response Operation mode which need to be operated by temperature rise at inner...

Page 12: ...Defrost heater Comp and Freezer Refrigertor Fan is off For 5 min Compressor is on Heater is off Defrost Precool Heater Defrost Pause Fan Motor Delay 2 Refrigerator Defrost Process Until Ref Defrost se...

Page 13: ...1 minutes and Humidity is over 70 Total compressor running time on time off time is 80hours Compressor running time on time only is 60hours Defrost Freezer Start Comp running time 10 12 60h 4 hours p...

Page 14: ...minutes and Humidity is over 70 Total compressor running time on time off time is 50hours Compressor running time on time only is 40hours Defrost Refrigerator Start Comp running time 4 6 40h 4 hours...

Page 15: ...ug out 3 Compressor RPM Control 1 Compressor RPM is dependent on RT Room Temperature appliance state Dial setting and Step Valve position Plug in Defrost Pull Down Compressor RPM RT sensor is below 29...

Page 16: ...when door opening This function is active after 2 hours plug in 3 Frz Fan Off After 3 minutes from Off condition 4 Ref Fan Off After 3 minutes from Off condition 3 Step Valve Control 1 Set the starti...

Page 17: ...Frz Set button 10 times while holding the Ref Set button 2 Control All electrical component is OFF But each door opening makes each fan motor ON Door Open Fan ON Door Close Fan OFF 3 Display Other Fun...

Page 18: ...inutes operation max time limit back to Fish mode 3 Damper Control Damper is controlled by Refrigerator sensor and Multi Crisper Internal sensor Other Functions Ref Sensor Multi Crisper Sensor Demaper...

Page 19: ...Display 3 How to exit this mode 1 Push the LOCK button 2 After 4 minutes automatically exit 4 Error Code No 1 2 3 4 5 6 7 8 9 10 11 12 13 Display Error Code Remark F 1 Freezer sensor disconnection or...

Page 20: ...ol Defrost heater is ON for 30 minutes 5 d F d r d H d 2 error Door switch Cause When door is opening for more than 1 hour Control Discard all information from doow swtich 6 C 1 error Cause After comp...

Page 21: ...n No operation 13 F 3 error Freezer Compartment Cause Defrosting is active for 80 minutes maximum limit time Control Reduce defrosting operation time to 30 minutes 14 r 3 error Refrigerator Compartmen...

Page 22: ...se When sensing ice drop 3 times in level sensor switch error Control Stop ice maker FUNCTIONS Error Display After 1 time rotation EA error code disappear if level swtich is normal 11 Eu error Cause S...

Page 23: ...ode After pushing Lock button A S Deforsting Mode Ref Set 5 times while pushing Frz Set Pull Down Mode Lock 10 times while pushing Ref Set Demo Mode Function Key Frz Set 10 times while pushing Ref Set...

Page 24: ...Wiring Diagram 23...

Page 25: ...1 Inner LED Lamp Refrigerator LED Lamp Disassemble assemble each parts Freezer LED Lamp Take out the LED window Unscrew 2 point Exchange LED PCB 24...

Page 26: ...Option Parts Multi Crisper LED Lamp Ionizer LED Lamp Disassemble assemble each parts Take out the LED cover Unscrew 2 point Disassemble LED cover pushing back side Unscrew 2 point p Exchange the LED...

Page 27: ...4ea Unscrew 4 points Disassemble with pushing the hook Pull out Freezer Louver with proper tools Disconnect the wire Disconnect the wire from the Freezer Louver check wire harness disconneted or not...

Page 28: ...screw 3ea Unscrew 7 points Disassemble with pushing the hook Pull out Refrigerator Louver with proper tools Disconnect the wire Disconnect the wire from the Freezer Louver check wire harness disconne...

Page 29: ...ssemble assemble each parts Remove screw cap screw 1 point Freezer inner LED Panel Defrost sensor Freezer Fan Defrost Heater Temp fuse include Pull out Freezer Louver B Freezer compartmnet evaporator...

Page 30: ...each parts Remove screw cap screw 2 point Ref inner LED Panel Ionizer option Ref Fan Defrost Heater Temp fuse include Defrost sensor Ref Damper option Pull out Ref Louver B Disconnet all wire harness...

Page 31: ...1 2 Remove Frz Louver A Previous page Disassemble assemble each parts Remove 4ea screws Disassemble with holding the hook Disasseble the Fan Motor Remove the spring from the Fan Unscrew 2 points Remo...

Page 32: ...or 1 2 Remove Ref Louver A Previous page Disassemble assemble each parts Remove 4ea screws Disassemble with holding the hook Disasseble the Fan Motor Unscrew 2 points Remove the spring from the Fan Re...

Page 33: ...age 1 Pull out the case Disassemble assemble each parts Cut the Sealing material Remove 2 screws disassemble Damper Cover Remove the Air Return Cover pushing the mark point Remove Damper As Remove Ion...

Page 34: ...ts Disconnet the housing Step Valve As Step Valve Connector Pull out the Step Valve As Yellow Yellow Blue Blue When assembling the Step Valve As check capi pipe color Cut the Capi pipe 2 point Remove...

Page 35: ...parts Unscrew 5 points Door Switch Remove door switch arrow direction with flat tool Humidity Sensor 4 Exchange any defected parts Disconnect wire harness Door Switch Humidity sensor RT sensor Door Sw...

Page 36: ...12 FCP Panel Disassemble assemble each parts Remove upside 1 screw Lift up FCP Panel about 10 cm Disconnect the wire harness about 10 cm Holding the topside and rotate the FCP Panel CCW 35...

Page 37: ...and compressor Remove refrigerant Residuals Tools Contents Process Installation should be conducted in accordance with the standard installation procedure Leave space of more than 5 cm from the wall f...

Page 38: ...Use of tools Precautions Items Process Compresso Evaporato Drye High Pressure Low pressure Suction Discharge tube Condense Hot 1 Nitrogen only should be used when cleaning inside of cycle pipes insid...

Page 39: ...harge tube Condense Hot Evaporato When replacing a drier Weld 1 and 2 parts by blowing nitrogen 0 1 0 2kg cm2 to high pressure side after assembling a drier When replacing a compressor Weld 3 and 4 pa...

Page 40: ...h a vacuum pump 3 Measure the amount of refrigerant charged Measure the weight of an evacuated bombe with an electronic scale Charge refrigerant into a bombe and measure the weight Calculate the weigh...

Page 41: ...Standard Regulations for Heavy Repair a cover back M C after completion of work y 1 Observe the safety precautions for gas handling 2 Use JIG or wet towel in order to prevent electric wires from burni...

Page 42: ...COVER HI T PP 1 9 301099AA00 CAP CAB COVR R PP 1 10 301099A900 CAP CAB COVR L PP 1 CABINET PART CODE PART NAME SPEC Q ty NO 11 30143KT030 PCB MAIN AS CEM 1 195X153 1 6T 1 12 301149CX10 COVER M PCB BOX...

Page 43: ...89LR 1 12 3014478800 PIPE WICON AS 8ROWS CONDENSER 1 13 3016808150 DRYER AS FR T89LR 1 14 3013227500 HOSE DRN F R B PE 2 15 3011347410 CORD POWER AS CP 2PIN 250V 10A 1 16 301149C810 COVER MACH RM AS P...

Page 44: ...Q ty 10 3011442620 COVER F SENSOR ABS WHITE 2 11 30143MAR00 PCB FRE LED AS 5 LED FR 4 125X20X1 6T 3PIN 1 12 3015522700 WINDOW F LED T ABS 1 13 3017860110 SHELF F A AS FILM METAL DECO OPTION 2 14 30178...

Page 45: ...522700 WINDOW F LED T ABS 1 14 301149CH00 COVER R IONIZER LAMP AS FR T88LR 1 15 30143MA700 PCB LAMP AS 3 LED FR 4 118X16X1 6T 2PIN 1 16 3001425900 COVER R LAMP GPPS 1 17 3017860310 SHELF R A AS FILM M...

Page 46: ...GERATOR DOOR R1 DOOR F DOOR R1 DOOR 10 3019067700 POCKET R M GPPS 1 11 3019067810 POCKET R CAN GPPS SILK PRINT 1 12 3019067730 POCKET R M GPPS SILK PRINT 1 13 3014252120 PANEL F CONTL AS ENGLISH 1 14...

Reviews: