Daewoo FR-033RVBE Manual Download Page 4

2

2.

INSTALLATION 

2.1

Loca

tio

When 

selecting

 a posi

ti

on  for your unit, please make  sure the 

oor is 

at and 

rm. The room 

should  be  well  ven

ti

lated with  an  ambient  room temperature  between  61°F and  100°F.   Avoid 

loca

ting

 your unit near a heat source, e.

g

. cooker, boiler or radiator. Also avoid direct sunli

g

ht as it 

may increase the electrical consump

ti

on. Extreme cold temperatures may cause the unit not to 

perform properly. This unit is not desi

g

ned for use in 

g

ara

g

e or outdoor installa

tion.

 Do not drape 

the unit with any coverin

g

.

  

Please keep a clearance of 8 inches on both sides, 6 inches in the rear and 8 inches above the unit. 
This  allows  for  proper  air  circula

ti

on  around  the  refri

g

erator  and  improves  the  unit’s  coolin

g

 

e

ciency. The door can be opened to the r

ig

ht or the le

ft,

 

depending

 on what be

tt

er suits the 

loca

ti

on. Please ensure there is adequate space for the door to fully open. 

2.2

Reversing the Door Swing 

Tools Required:

 

Phillips style screwdriver / Flat blade screwdriver / Hexa

g

onal spanner 

We recommend that 2 people handle the unit for door reversal. 
Be sure the unit is unplu

gg

ed and empty. 

Tilt the unit backwards and rest the unit on somethin

g

 solid so that it will not slip. Do not lay 

the unit 

at on its back as this may dama

g

e the coolant system. 

Adjust the two levelin

g

 feet to their hi

gh

est posi

ti

on. 

All parts removed must be saved for reinstalla

tion

 of the door. 

 

1) Remove the plas

ti

c coveri

ng

 from the top door hin

g

e.

2) Unscrew the three screws from the bo

tto

m bracket.

3) Remove the foot from opposite side. 

4) Place to one side. 

 

Summary of Contents for FR-033RVBE

Page 1: ...FR 033RVBE FR 033RVWE ...

Page 2: ...Contents 1 SAFETY WARNINGS 1 2 INSTALLATION 2 3 PRODUCT OVERVIEW 4 4 OPERATION 5 5 CLEANING 6 6 MAINTENANCE 6 7 TROUBLESHOOTING 7 8 TIPS FOR ENERGY SAVING 7 9 DISPOSAL 8 ...

Page 3: ...ot be made by children without supervision 8 If the supply cord is damaged it must be replaced by the manufacturer its service agent or similar qualified persons in order to avoid a hazard 9 Please abandon the refrigerator according to local regulations as the unit contains flammable blowing gas and refrigerant 10 Follow local regulations regarding disposal of the appliance due to flammable refrigera...

Page 4: ...nd the refrigerator and improves the unit s cooling efficiency The door can be opened to the right or the left depending on what better suits the location Please ensure there is adequate space for the door to fully open 2 2 Reversing the Door Swing Tools Required Phillips style screwdriver Flat blade screwdriver Hexagonal spanner We recommend that 2 people handle the unit for door reversal Be sure t...

Page 5: ... seals are closed on all sides before final tightening of the bottom hinge 12 Adjust the leveling feet as needed 2 3 Door Space Requirements The unit s door must be able to open fully as shown W D 35 5 in 31 5 in 2 4 Levelling the Unit Adjust the two leveling feet at the front of the unit If the unit is not leveled the door and magnetic seal alignments will not be covered properly 2 5 Cleaning Bef...

Page 6: ... allowing the coolant to settle 2 7 Interior Accessories Various glass or plastic storage shelves are included with your appliance different models have different combinations In order to make the most of the storage volume you can remove shelves or drawer according to your usage needs It is recommended to place one of the full size shelves in the lowest set of guides and keep it in this position 3 ...

Page 7: ...akes some unusual noises Most of these are perfectly normal but you should be aware of them These noises are caused by the circulation of the refrigerant in the cooling system It has become more pronounced since the introduction of CFC free gases This is not a fault and will not affect the performance of your unit This is the compressor motor working as it pumps the refrigerant around the system 4 ...

Page 8: ...e the unit The condenser grille located at the back of the unit and the adjacent components can be vacuumed using a soft brush attachment 5 3 Cleaning Tips Condensation may appear on the outside of the unit This may be caused by change of room temperature Wipe off any moisture residue If the problem still exist please contact a qualified technician for assistance 6 MAINTENANCE 6 1 Care When Handling...

Page 9: ...is is caused by the radiation of the condenser and it is a normal phenomenon Condensation condensation may be detected on the exterior surface and door seals when the ambient humidity is high This is normal Simply wipe out the condensing water with a dry towel Buzz the compressor will buzz during starting up or shutting down 8 TIPS FOR ENERGY SAVING Try not to open the door too often especially wh...

Page 10: ... refrigerant used in your unit and insulation materials require special disposal procedures Ensure that none of the pipes on the back of the unit are damaged prior to disposal Up to date information concerning options of disposing of your old unit and packaging from the new one can be obtained from your local council office When disposing an old unit break off any locks or latches and remove the d...

Page 11: ...FR 033RVBE FR 033RVWE www daewooelecusa com ...