1. How to enter this check mode
1) Push the LOCK button.
2) Push the WATER button 5 times while pressing the FRZ.SET button.
2. The Front LED displays the current error code ( if happens ).
; Every time you press the Freezer Set button, the following value display.
1) The appliance running time. ( From the plug in. )
2) Freezer sensor temperature.
3) Defrost sensor temperature.
4) Refrigerator sensor temperature.
5) Room temperature.
6) P Factor display.
3. How to exit this mode
1) Push the LOCK button.
2) After 4 minutes automatically exit.
Error Display
4. Error Code
No
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
; All Error Code reset, when the relative parts turn into normal.
Co
Pull-Down mode display (No error)
d2
Forced Defrost mode display (No error)
Eu
Full ice switch error
C1
Abnormal or defective cycle
F3
Return after defrosting : abnormal or defective
Et
Horizontal switch error
Eg
Water supply error
EA
Drop the ice while Et
dF
Freezer Door switch is defective.
dH
Home bar door switch is defective. ( *Home bar models only )
El
Ice sensor disconnection or short
rt
Room temperature sensor disconnection or short
d1
Defrost sensor disconnection or short
dr
Refrigerator Door switch is defective.
Display (Error Code)
Remark
F1
Freezer sensor disconnection or short
r1
Refrigerator sensor disconnection or short
11
Summary of Contents for FPS-X22D1 Series
Page 1: ......
Page 3: ...2 Outside Diemension SPECIFICATIONS The real features are model dependent 2 ...
Page 20: ...WIRING DIAGRAM Inverter Compressor 19 ...
Page 21: ...WIRING DIAGRAM Non Inverter Compressor 20 ...
Page 27: ...Evaporator in detail How to Disassemble Assemble for each part 26 ...
Page 29: ...7 Refrigerator Damper changing method How to Disassemble Assemble for each part 28 ...
Page 33: ...2 Freezing or cooling failure Weak cooling TROUBLE SHOOTING 32 ...
Page 36: ...6 Dews on Refrigerator Compartment TROUBLE SHOOTING 35 ...
Page 37: ...5 Refrigeration failure Foods does not get cool or cold soon TROUBLE SHOOTING 36 ...
Page 49: ...COOLING CYCLE HEAVY REPAIR Brzing Reference Drawings 48 ...