7-10. Control of R-sensor OFF Point
INPUT
CONTROL OBJECT
●
”J1” On Main PCB
●
Control Resistance of R sensor OFF Point
A. LOW COOLING OPTION
- When the refrigeration of refrigerator is poor or weak though Fan and COMP are working continuously,
the following actions are recommended for service.
●
Resistance (R39) : Default resistance (31.4Kohms)
●
Resistance (R36) : Cut the “J1” off to reduce basic resistance by 1.5
°
C. (2K
Ω
up)
●
Resistance (R31) : Cut the “J2” off additionally to reduce basic resistance by 1.5
°
C. (total 4K
Ω
up)
R39 = R-SENSOR OFF point
R36 + R39 = R-SENSOR OFF point - 1.5
°
C
R31 + R36 + R39 = R-SENSOR OFF point - 3
°
C
R-SENSOR
R47(31.4K)
R45(2K)
J1
R39(31.4k)
R36(2k)
J2
R42(2K)
R31(2k)