Nº
FUNCTION
CONTENTS
5 6
Pcb Control Functions
7
DETERMI-
NATION OF
DEFROST
1) Starting condition of Defrost Mode
1.1- When accumulated running time of comp. is 12hrs.
1.2- After checking the condition ‘1.1’ if total time(COMP on time + COMP
off time) is more than 48hrs, then defrost mode starts
immediately.
1)General Defrost Mode
1.1- Start: by determination of defrost
1.2- Process: general operation heater on pause(6 min) general
operation.
Heater defrost: when the temperature at D-sensor is over 10°C, heater
turns off.
Limit time: If the system is on D-sensor error, heater is off by time(30
min).
D2 error: 80 min in defrost position (defrost problem).
2)Forced Defrost Mode
2.1- Start: by press TEMP. CONTROL button for 5 seconds continuously.
2.2- Process: same as General Defrost Mode
General Defrost Mode is on for initial 30 seconds after heater is on.
(for TEST)
1) When power is on, if the temperature at the D-sensor is under 3.5°C, then
General Defrost Mode starts.
1) RT
≤
24: The COMP can’t be on within 30 min after comp. is off even
though R-sensor is on condition.
(This is to protect comp.) FUNCTION of LOW RT.
2) RT > 24: The COMP can’t be on within 6 min after comp. is off even
though R-sensor is on condition.
(This is to protect comp.)
1) D1 ERROR (It happens when D-SENSOR is OPEN or SHORT)
1.1- DISPLAY: FREEZER RED LED lamp in on & off one time.
1.2- CONTROL: return to the limit defrost time of Defrost (30 min).
2) D2 ERROR (It happens when heater is off by time (80 min).
2.1- DISPLAY: FREEZER RED LED lamp in on & off two times.
2.2- CONTROL: Return to the limit defrost time of Defrost (80 min).
3) R1 ERROR (It happens when R-SENSOR is OPEN or SHORT).
3.1- DISPLAY: REFRIGERATOR RED LED lamp in on & off one time.
3.2- CONTROL: controlled by the condition of RT
3.3- CANCEL: when R-SENSOR is working normally.
4) RT ERROR (It happens when RT-SENSOR is OPEN or SHORT)
8
DEFROST
MODE
9
INITIAL
DEFROST
10
PREVENTION
OF COMP.
RESTART
11
ERROR
DISPLA Y
&
CONTROL
RT-S TEMP
RT-S ERROR
~24ºC
25ºC ~40ºC
COMP. work rate (%)
40%
30%
44%
ON/OFF (min)
20 / 30
15 / 35
22 / 28
NOTE
ERROR
Low RT TEMP
General
Summary of Contents for ERF-384
Page 1: ...Manual de servicio Refrigeradores Modelo...
Page 3: ......
Page 5: ...2 EXTERNAL DRAWINGS 4 1 ERF 334M 2 ERF 364A M 384A M 394A M 414A M 367A M 387A M 397A M 417A M...
Page 6: ...5 3 WIRING DIAGRAMS 1 ERF 334M 2 ERF 367A 387A 397A 417A...
Page 7: ...6 3 ERF 364A 384A 394A 414A 4 ERF 364M 384M 394M 414M...
Page 23: ...22 9 EXPLODE DRAWINGS 1 ERF 334M...
Page 24: ...23 Explode drawings...
Page 27: ...EXPLODE DRAWINGS 26 2 ERF 384M...
Page 28: ...Explode drawings 27...
Page 31: ...30 EXPLODE DRAWINGS 3 ERF 364M ERF 394M ERF 414M...
Page 32: ...31 Explode drawings...
Page 35: ...34 EXPLODE DRAWINGS 4 ERF 384A...
Page 36: ...35 Explode drawings...
Page 39: ...38 EXPLODE DRAWINGS 5 ERF 364A ERF 394A ERF 414A...
Page 40: ...39 Explode drawings...
Page 45: ...44 EXPLODE DRAWINGS 6 ERF 387A...
Page 46: ...45 Explode drawings...
Page 49: ...48 EXPLODE DRAWINGS 7 ERF 367A ERF 397A ERF 417A...
Page 50: ...49 Explode drawings...
Page 60: ...59 12 MAIN PCB DIAGRAM ERF 364A 384A 394A 414A...
Page 66: ...65 12 MAIN PCB DIAGRAM ERF 367A 387A 397A 417A...
Page 67: ...66...