![Daewoo ERF-331MM Manual Download Page 26](http://html1.mh-extra.com/html/daewoo/erf-331mm/erf-331mm_manual_3367724026.webp)
26
NO CONTROL FUNCTION
CONTENTS
Pcb Control Functions
12
R-sensor
-
When refrigerator is over-cool or weak-cool, it is adjusted the
off point adjusting option
option condition by R42 and R43(after deleting j7)
13
Functions of low
1) Low temp.: RT SENSOR
≤
24ºC
temperature
2) Hysteresis DIFFERENCE: 1ºC
1- Mode of low temp. : RT SENSOR
≤
24ºC
2- Mode of general temp.: RT SENSOR
≥
25ºC
3- Mode of just before control : 24
≤
RT-S<25ºC
ex) 1- Mode of general control when is arriving to 24ºC
2- Mode of low control when is arriving to 25ºC
3) Control
1- When comp. is on, R-s HTR is off
2- The comp can't be on whiting 30 min after comp. off
3- At general temp. Mode of RT error, R-s HTR is off
4- At low temp. mode, R-s off point increase
2 degrees (ex) -0.5 to 1.5 C
4) R-s heater initial Operation
1- R-s heater turn on and off four times for 8 sec.
14
Time charts of low
1. LOW RT MODE (RT-S
≤
24ºC )
temperature
A) D-S
≤
3.5ºC & R-S ON point condition (Initial operation)
R42
R43
R41
J7
CC16
8 PIN
MICOM
Micom
input
(V)
Off
point
variation
(deg)
R42,
R43
(KG)
0V
1.0V
1.5V
2.0V
2.5V
3.7V
5.0
-0.5 ºC
1.0
2.0
3.0
1.0
2.0
3.0
default
R42:40
R43:10
R42:23.3
R43:10
R42:153
R43:10
R42:10
R43:10
R42:3.5
R43:10
R42:10
R43:–
ON POINT
OFF POINT
HTR ON
COMP OFF
COMP ON
OFF
6min
6min
24min ON
OFF
HTR ON
Pausa
COMP OFF
R-S
Comp
HTR
R-S
Heater
Summary of Contents for ERF-331MM
Page 3: ...1 ERF 331 MM 2 ERF 361AM MM 391AM MM 411AM MM 3...
Page 4: ...4 3 WIRING DIAGRAMS 1 ERF 331MM 2 ERF 361MM 391MM 411MM 3 ERF 361AM 391AM 411AM...
Page 12: ...PLANO DE DESPIECE 1 ERF 331MM...
Page 15: ...ERF 361AM 391AM 411AM 15...
Page 18: ...ERF 361 MM 391 MM 411 MM 18...
Page 29: ...13 MAIN PCB DIAGRAM 29...