7
Optical Interlinked Smoke Alarm
Model No. ELA1380
User Manual
IMPORTANT
–
RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
Troubleshooting Guide
Problem
Possible Cause
Possible Solution
Alarm triggers as soon as the
battery is inserted
High concentration of
smoke
Clear smoke and re-insert the
battery
Alarm beeps every 40
seconds
Low battery voltage/flat
battery
Replace with a new CR123A
battery
Alarm beeps twice every 40
seconds
Alarm is faulty
Replace Alarm
No alarm when the test
button is pressed
Battery installed incorrectly Check battery is inserted the
correct way round
Battery flat
Replace with a new CR123A
battery
Technical Specification
Battery Safety and Warnings
•
CAUTION
: There is a danger of explosion if the batteries are incorrectly fitted.
•
Ensure that the batteries are installed with the correct polarity.
•
It is recommended that batteries are removed if the alarm is not to be used for
a long period of time or if the alarm is to be disposed of.
•
Replace only with the same or equivalent battery type.
•
Do not expose batteries to sunshine, fire, heat or similar, never dispose of
batteries in a fire.
•
Do not charge non-rechargeable batteries.
•
Do not short-circuit batteries.
•
Exhausted batteries are to be removed from the product and safely disposed of.
WARNING!
•
Keep new and used batteries away from children and animals.
Model Number
ELA1380
Operating Voltage
DC 3V
Battery Capacity
1400mAh
Battery Type
CR123A*
Battery Life
5 Years (typical)
Average Quiescent Current
<20uA
Alarm type
Sounder and LED Indicator
Alarm Sound Level
≥85dB @3m
Wireless Frequency
868.3Mhz
Wireless Operating Distance
100m (clear line of sight max.)
Operating Humidity
≤95% (Non
-Condensation)
Operating Temperature
-10°C
–
55°C
Dimensions (Approx.)
28.5mm (h) x 76mm (w) x 76mm (d) Approx.
Weight (Approx.)
83g (with battery)
This product conforms to the Radio Equipment Directive 2014/53/EU
Tested to EN 14604:2005 & EN 14604:2005/AC:2008