62
Thermostat Hi–Limit
1. Function
Ŗ6JKUKUCDKOGVCNŌV[RGUYKVEJYJKEJUVQRUVJGDWTPGTQXGTJGCVKPI
Ŗ+HVJGDWTPGTKUVQQJQVVJKUVJGTOQUVCVUJWVUQHHVJGICUXCNXGUCPFCHVGTVJG
burner is cooled down, it allows the gas valves to operate.
2. Specification
Ŗ#DKOGVCNVJGTOQUVCVYKVJVJGVGTOKPCNUPQTOCNN[EQPPGEVGF
Ŗ'NGEVTKETCVKPI#CV8
Ŗ1RGPKPIVGORGTCVWTGu%%NQUKPIVGORGTCVWTGu%
Ŗ6[RGPCOG6
3. Checking method of mal–function
Ŗ#HVGTQRGTCVKPICKTFT[RTQITCOHQTOKPWVGUQTNQPIGTVJGVGTOKPCNUVCVWUQHVJKURCTVOWUVDGUJQTV
Ŗ2CTVKUFGHGEVKXGCPFVQDGTGRNCEGFKHTGUKUVCPEGDGVYGGPVGTOKPCNUOGCUWTGFCHVGTUGRCTCVKPIECDNGU
connected to sensor flame is 1
š
or more.
4. Procedure of replacement
①
Remove plate top.
②
Remove panel F ass'y.
③
Remove cabinet front ass'y.
④
Remove frame upper.
⑤
Remove drum ass'y.
⑥
%JGEMCVVCEJOGPVRQUKVKQP
⑦
Separate the connected cable and unfasten 2 screws
to separate parts.
⑧
Assemble part in reverse order of the above
procedures.
Part Code : 3619047610
Thermostat–Limit