4
PULSATOR SYSTEM
When the new shaped pulsator is rotated C.W or C.C.W at a high speed, it makes the 'heart-shaped' water currents as
shown below.
AUTOMATIC DRAINING TIME ADJUSTMENT
This system adjusts the draining time automatically according to the draining condition.
FUNCTIONAL PRINCIPLE
1. The micom can remember the time from the beginning of drain to reset point when the pressure switch reaches to
"OFF" point.
2. In case of continuous draining, residual drain time is determined by micom.
Draining time as a whole=D + 60
(T sec.)
WATER CURRENTS
A Water is pushed up near the tub
wall by rotation of the pulsator.
B Water is pulled down in the middle
of the tub by rotation of the
pulsator
C Water currents is generated by
rotation of the pulsator.
C
Rotate
A
A
B
Good draining
The washer begins spin process after drainage.
Draining
Bad draining
Draining time is prolonged.
condition
No draining
Program stops and gives the alarm.
Drain Time
Movement of the Program
Less than 5 minutes
Continue draining.
More than 5 minutes
Program stops and gives the alarm with all lamps of the "COURSE" light up.
Residual drain time.
The time remembered by micom.
DRAINING
TIME
WATER
LEVEL
T4
T3
T2
T1
TRIP POINTS
RESET POINTS
*
*
*
*
*
*
*
*
LOW
MED
HIGH
0
60
160
220
280
(mm)
340
60
D1
D2
D3
D4
T1=D1+60 (Sec.) T2=D2+60 (Sec.) T3=D3+60 (Sec.) T4=D4+60 (Sec.)
SMALL
Summary of Contents for DWF-4220 Series
Page 57: ...56 BARE PCB TOP BOTTOM...