42
6. Abnormality Notification
6-1. IE (Input Error) - Error in water supply
1) Conditions of Occurrence
①
In case the designated water level is not reached in 5 minutes during water supply or re-supply
2) All LEDs are turned off and 'IE' blinks in18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error display is cleared when turning off/ on power.
6-2. OE (Output Error) - Error in drainage
1) Conditions of Occurrence
①
In case water level does not reach reset point in 10 minutes after drainage starts
2) All LEDs are turned off and 'OE' blinks in 18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error display is cleared when turning off/ on power.
6-3. UE (Unbalance Error)
1) Conditions of Occurrence
①
In case main spin-drying is not reached within 20 cycles of balance spin-drying
②
In case balance spin-drying fails during interim spin-drying, UE occurs as the cycle moves to the next
process.
2) All LEDs are turned off and 'UE' blinks in 18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error mode is cleared by opening door and organizing the laundry in spin-dry chamber, closing door and
pressing start/ temporary stop button. Then, spin-drying begins again.
Summary of Contents for DWD-WD125 Series
Page 48: ...47 PCB PIN ARRANGEMENT...
Page 60: ...59 6 BLDC Motor 7 Power Transmission System of BLDC Motor...
Page 65: ...64 Wiring Diagram...
Page 71: ...70 PLATE TOP ASS Y 1 Remove 3 screws 2 Remove 4 screws...
Page 73: ...72 VALVE 3WAY 1 Remove 4 screws 2 Separate 3 connectors 3 Separate 3 hose clamps...