background image

15

4. CABINET ASSY

Summary of Contents for DWD-E115R

Page 1: ...DRUM WASHING MACHINE DEC 2006 DWD E115R DWD E113R WDE115R001...

Page 2: ...RUM 2 2 SPECIFICATION OF DRUM WASHING MACHINE 6 3 VERIFICATION OF DRUM ASSY 8 4 SEQUENCE CHART OF PCB 24 5 TROUBLE SHOOTING 34 6 WIRING DIAGRAM 49 7 TROUBLE SHOOTING REGARDING DRAIN 50 8 INSTALLATION...

Page 3: ...NANO technology Sterilizing up to 99 9 No damage and entanglement but excellent washability 4way savings noise vibration washing times energy Self cleaning course of Drum Good washing performance with...

Page 4: ...3 DD CONTROL DIRECT DRIVE SYSTEM BLDC MOTOR 3 THEDIRECTDRIVESYSTEMOFDRUMWASHINGMACHINE TUB DRUM LIFTER WASH BLDC DRAIN PUMP MOTOR...

Page 5: ...ADDING CLOTHES LOCK HINGE DOOR AS GLASS GASKET 7 DRAIN PARTS DRAIN PUMP MOTOR VALVE HOUSING DRAIN HOSE I 6 DRY PARTS HEATER DRY OPTION BLOWER FAN FAN MOTOR BLDC THERMISTOR THERMOSTAT FUSE BI METAL CO...

Page 6: ...E FILTER POWER CORD 15A 2 DRIVE PARTS BLDC MOTOR DRUM BEARING SPIDER SHAFT TUB WEIGHT BALANCER 4 WASH HEATING WASH HEATER OPTION THERMISTOR 40 C FIXED TEMP CONTROL OPTION 60 C 90 C BOIL 8 SUPPORTER BA...

Page 7: ...T F ASSY CABINET F AS 1 PANEL F ASSY 2 INLET BOX AS INLET BOX 2 INLET BOX AS 3 WAY INLET VALVE 2 WAY INLET VALVE 1 WAY INLET VALVE 4 CABINET AS 7 DOCT AS DUCT AS 7 DOCT AS DUCT AS 5 BASE U AS 6 TUB AS...

Page 8: ...5 BASE U AS PCB MAIN AS 6 TUB ASSY DRUM AS 6 6 6 3 6 4 6 1 6 2 6 8 6 7 6 4 6 5 6 TUB ASSY Parts For Driving 6 1 BLDC ROTOR BLDC MOTOR 6 2 BLDC STATOR 6 3 SHAFT 6 4 BEARING Parts For Transmitting 6 5...

Page 9: ...Digital condensing dry system OPERATION WATER PRESSURE 29kPa 784kPa 0 3kgf cm2 8kgf cm2 1 PREMIUM TYPE 2 DRUMWASHINGSPECIFICATIONOFMACHINE 1 EXTERIORDIAGRAM NO PARTSNAME 1 FRAMEDOORO 2 DOOR GLASS PLAT...

Page 10: ...YPE DRUM TYPE DRY TYPE Digital condensing dry system OPERATION WATER PRESSURE 29kPa 784kPa 0 3kgf cm2 8kgf cm2 2 LUXURY TYPE 1 EXTERIORDIAGRAM NO PARTSNAME 1 FRAMEDOORO 2 DOORPLATEGUIDE 3 PROTECTOR GL...

Page 11: ...0RP 1 A03 CASEPCBF 3611143600 HIPS 1 A04 PCBAS PRPSSW2D21 DWD E110RFRONTPCBASSY 1 A05 BUTTONDIALAS 3616634700 130RP SBUTTONDIALAS 1 A06 HOLDERDIAL 3613052100 HIPS 1 A07 CASEHANDLE 3611143800 ABS 1 A08...

Page 12: ...PCB F 3611143600 HIPS 1 A04 PCB AS PRPSSW2D24 DWD E112R FRONT PCB ASSY 1 A05 BUTTON DIAL AS 3616634700 130RP S BUTTON DIAL AS 1 A06 HOLDER DIAL 3613052100 HIPS 1 A07 CASE HANDLE 3611143800 ABS 1 A08...

Page 13: ...NLET 3613271000 EPDM 1 B07 HOSE A 3613266640 EPDM ID 10 L 280MM MAIN B110RN 1 B08 HOSE B 3613266740 EPDM ID 10 L 370MM HOT B110RN 1 B09 HOSE C 3613267040 EPDM ID 10 L 160MM SHOWER B110RN 1 B10 PIPE JO...

Page 14: ...11 3 CABINETFASSY 1 PREMIUM TYPE...

Page 15: ...0V16A BITRON 1 C06 FRAMEDOORO 3612207300 ABS 1 C07 FRAMEDOORI 3612207400 ABS 1 C08 DOORGLASSPLATE 36117ABJ00 GLASS 1 C09 DOORGLASS 361A110600 GLASS DWD 100DR 1 C10 CUSHIONDOOR 3611568400 DWD E110RP 3...

Page 16: ...13 3 CABINETFASSY 2 LUXURY TYPE...

Page 17: ...7200 DL S1 250V16A BITRON 1 C06 FRAMEDOORO 3612207800 ABS 1 C07 FRAMEDOORI 3612207400 ABS 1 C08 DOORPLATEGUIDE 36117ABL00 ABS 1 C09 PROTECTORGLASS 3618304201 ABSTRANSPARENT 1 C10 DOORGLASS 361A110600...

Page 18: ...15 4 CABINETASSY...

Page 19: ...R 1 D04 CABINET 3610810900 SGCD1 0 8 925 7 1922 PAINTING DWD 110RP 1 D05 COVERBACKAS 3611425510 COVERBACK PADCABINETAS 1 D06 STOPPERSPRING 3615202200 POM DWD 100DR 4 D07 FIXTUREPLATE 3612008000 130RP...

Page 20: ...17 5 BASEUAS...

Page 21: ...910 PP DWD 100DR 1 E05 SUPPORTERLEG 3615303600 PO 3 0T 4 E06 FIXTURELEG 3612006400 ABS DWD 100DR 4 E07 SPECIALBOLT 3616029000 10X1 25 51MM 4 E08 FOOT 3612100600 BUTYL DWD 100DR 4 E09 ABSORBERBASE 3610...

Page 22: ...19 6 TUBASSY...

Page 23: ...361A400350 DWD A11 S LIFTBODY FILTERAS 3 F17 SPIDERAS 361A300200 11KG 1 F18 GASKETTUB 3612321100 EPDMFORM 1 F19 DRAINMOTOR 36196TAJ00 SV MX7T20D220 50 60ST23 56 5 1 F20 VALVEDRAINAS 3615415100 DWD 100...

Page 24: ...21 7 DUCTBAS DUCTPIPEAS...

Page 25: ...361A201800 ALDC 1 G11 PACKING THERMOSTAT 3614009900 SILICON DWD 100DR 1 G12 SWITCH THERMOSTAT 3619046500 ON120 C OFF150 C 230V 15A VDE 1 G13 HEATER DRY 3612800900 220V2100W23 05OHM6 1W SQINCOLOY8001R1...

Page 26: ...Y No PARTS NAME PARTS CODE DESCRIPTION Q TY REMARK H01 PLATE T 3614539500 SECD 1 2T 1 H02 LABEL CAUTION 3613553830 DRUM 11KG DRY WASH KOR PVC 95 143 SILK 2 1 H03 LABEL INSTALL 3613555700 ART OPP WATER...

Page 27: ...min Mid Spin 3min Water Supply 2min Rinse 2 3min Drain 1min Balancing Spin 2min Mid Spin 3min Water Supply 2min Rinse 3 3min Drain 1min Balancing Spin 2min 7min Main Spin 5min 3min Crease care 60sec E...

Page 28: ...n Mid Spin 3min Water Supply 2min Rinse 2 3min Drain 1min Balancing Spin 2min Mid Spin 3min Water Supply 2min Rinse 3 3min Drain 1min Balancing Spin 2min 7min Mid Spin 5min 3min Crease care 60sec Dry...

Page 29: ...id Spin 3min Water Supply 2min Rinse 2 3min Drain 1min Balancing Spin 2min 7min Main 5min 3min Crease care 60sec END 10sec Remain Time Display 1 27 1 30 1 35 1 30 NOTE S t e a m W a s h i n g R i n s...

Page 30: ...g the same 45 rpm with left and right direction alternatively 2 Attaching stop Attaching the laundry to drum inside with constant speed 3 Unbalance checking point First step check the U B at 95 rpm 16...

Page 31: ...sec pulse until unlock 3 After door locking all parts can work normally 4 After pressing power button if the temperature of wash thermistor is over 50 C or the water level is over the safety level the...

Page 32: ...isplay LOCK off Dooropen drain fanmotoron coldwatersupply waterlevelis lessthansafetylevel NO NO YES YES Temperatureis lessthan50 C 2 DOOROPENSYSTEM 1Ifaddthelaundryduringwashing pressthedoorunlockbut...

Page 33: ...mode press TEMP and DRY simultaneously 2 5 The sequence of drain 1 If the checking time to reset point is below 1 min the remaining drain time is 30 sec 2 If the checking time to reset point is over...

Page 34: ...rnon LOCK signal allprocessisconductingnormaly 2Whenworkingstarts thePCBdisplaysallthesensorconditions 3Inthiscase BLDCMotorisnottested Inordertotestit selectspinorrinse 2 Continoustestingmode 1 Proce...

Page 35: ...ressure is inferior sensor pressure The drain motor dose not work Change the drain motor The drain motor is an inferior product or broke down The fan motor does not work Change the fan motor The fan m...

Page 36: ...istor wash The water temp is over 45 C in delicate wool course Change the thermistor wash The heater wash dose not work Change the heater wash The water temp doesn t rise over 2 C during 15min The hea...

Page 37: ...y assembled Openthewatertap Cleanthefilter ChangetheInlet Valve Thecontactofthe Connector ChangetheInlet Valve ChangetheSensor Pressure Changethebad parts ChangetheInlet Valve ChangetheInlet Valve IE...

Page 38: ...heckthehosecondition checktheconnectorcondition frequencyCheck refertobelow connectorbroken Checkingmethodofcoilregistance harness connector E2 overflowerror Waterlevelishigherthanoverflowlevelbecause...

Page 39: ...placeDOORAS ReplaceDOORS W AssembleConnector InsertReceptacleno 2 orno 3 ReplaceDOORS W Afterdrainingwater openthedoor LE LE LE LE LE LE LE checkthejoiningstatusof connectorbyeye Ticksoundhappen check...

Page 40: ...37 2 CheckingmethodofDOORLOCKSWITCH 3 CheckingmethodofDOORLOCKSWITCH 2345 Nono 1 BetweenNo 3 No 4 if156 234 itisnormal BetweenViloetandBluewire If156 234 itisnormal PIN array...

Page 41: ...the resistancebetweentwoendsis23 3 25 7 Checkwhetherdisconnectedornot SeeFig A Measuretheresistanceoftwoendsofthesensor if 11 981K atR25 itismormal Measuretheresistanceoftwoendsofthesensor if 11 981K...

Page 42: ...ng In Wool Lingerie courses sensing temp is over 45 C 6 H6 Abnormal condition of Heater Wash when the temp increase at 10 minutes after heater operation is under 10 C 7 H7 Abnormal condition of Heater...

Page 43: ...rivingmechanismofBLDCMOTOR BLDCMOTOR MagneticdensityflowofBLDCMotor SequencediagramofBLDCMOTOR 5 MOTOR Rotor Insulator Core Insulator electromagnet generatinghighpowerbyrotator apermanentmagnet andsta...

Page 44: ...6 DRY SYSTEM OPTION E J C D G F I B A H Division Parts Name A DUCTCOVER B FANMOTOR C HEATERDRY D DUCTBLOWER E VALVEINLET DRY F THERMOSTAT Bimetal G THERMISTOR TemperatureSensor H DUCTBUPPER I FANAS J...

Page 45: ...ONDENSINGDUCT andcondensedinDUCTcontactingWATERSUPPLY condensedwater isextractedthroughDRAINHOUSING Dryfunctionisperformedbycontinuousrepetitionofevaporatingandcondensingcirculationasabove DRY DUCT T...

Page 46: ...drying time is 166 min Drying Time is 150 210min according to Load Sensing Data STRONG Heater control temperature is 100 C On 110 C Off drying time is 216 min Drying Time is 210 270min according to L...

Page 47: ...ngtheairtemperature FAILUREMODE Theaircannotbeheatedeventhoughwaterissupplied H1 shotorcut off H3 airtemp isreachedover150 C CHECKINGMETHOD Checktheresistanceofthermistor replacewithnewone FUSETEMPERA...

Page 48: ...C andreoperatingheater byconnectingheaterpowersupplyifthetemperaturefallsunder120 C OPERATINGTEMPERATURE PICTURE UNITFANMOTOR function circulatingtheinsideairduringdryprocess SPEC PICTURE FAILUREMODE...

Page 49: ...onebeforethedryhadstarted Situation PCBshows H1 or H3 cause Thermistorisbroken Thermistorisshortorcut off countermeasures replacetheThermistor part name checking point checking results jurge repair me...

Page 50: ...eater replacetheFusetemp checking point part name checking results repaire method HEATER SENSORTEMP FUSE TEMP dryHeaterisshortorcut off Thermistorisshortorcut off FUSETEMPERATUREiscut off replacethe d...

Page 51: ...re replace fanmotor 1DisassembleDuctCoverAsfromDuctBAs Screw4EA 2DisassembleFANASFromDuctCoverAs Fixedby8mmNUT 3DisassembletheFANMOTOR SCREW3EA parts Control time MOTOR 10 sec On 10sec Off DRAIN MOTOR...

Page 52: ...49 DOUBLE VALVE BUBBLE DOUBLE VALVE N BUBBLE 6 WIRING DIAGRAM OPTION OPTION DRAIN PUMP Or DRAIN MOTOR DRAIN PUMP Or DRAIN MOTOR OPTION OPTION...

Page 53: ...ngdrainduring10min ThewaterlevelcannotreachtoRESETPOINTduring10minofdrain Checking Methods Check the hose drain O condition twisted or frozen Check the hose drain O condition blocked DRAIN MOTOR is br...

Page 54: ...AS by turning CCW direction Please keep FIXTURE UP DOWN AS for later use When fixing FIXTURE UP DOWN AS turn it CW direction PARTS NAME FIXTUREUP DOWNAS UNIT SERVICE WRENCH LEG ADJUST AS REMARKS SPECI...

Page 55: ...ingLEGADJUSTAS Adjusting Method Remarks If turned CW the LEG ADJUST AS moves the washer upward If turned CCW the LEG ADJUST AS moves the washer downward 5Afteradjustinglevel fixSPECIALBOLT Adjusting M...

Page 56: ...ngconditionbetween fixtureheateristight littlegaponleft right Atfasteningthenutforfixingtheheaterwash keeptheprotrusionlength ofboltto10 12mm ifunder10mm watercanleak andifover12mm fixtureheatercan de...

Page 57: ...2006 12 DRUM WASHING MACHINE DAEWOO ELECTRONICS CORP 686 AHYEON DONG MAPO GU SEOUL KOREA C P O BOX 8003 SEOUL KOREA TELEX DWELEC K28177 8 CABLE DAEWOOELEC...