background image

Limited Warranty

DAEWOO ELECTRONICS CORPORATION OF AMERICA warrants the following
window room air-conditioner to be free from defective material and workmanship and
agrees to remedy any such defect or to furnish a new part (at the Company’s option) in
exchange for any part of any unit of its manufacture which under normal installation,
use and service disclosed such defect, provided the unit is delivered by the owner to
store or dealer where purchased or Daewoo authorized service center. To establish
and receive warranty service at our store, dealer or our authorized service center, a
sales receipt or bill of sales is required for proof of purchase.

This warranty does not extend to any of our electronic products which have been
subjected to misuse, neglect, accident, incorrect wiring not our own, improper
installation, unauthorized modification, or to use in violation of instructions furnished by
us, nor units which have been repaired or altered outside of our factory, nor to cases
where the serial number thereof has been removed, defaced, or changed.

This warranty is in lieu of all warranties expressed or implied and no representative or
person is authorized to assume for us any other liability in connection with the sales of
our electronic products.

Over the counter exchange for units that are initially defective. Initial defective is
described as when the dealer opens the unit and finds that it is inoperative or an
individual customer opening a new unit and finding that it is initially defective. This unit
may be returned to the factory by the dealer for exchange. Under no circumstances
will an individual customer be permitted to return defective unit directly to factory.
Exchange must be directly with the dealer. When this unit is returned to dealer, a copy
of the purchase evidence stating the date of purchase is to be put in the individual box
for dealer’s further control with the factory.

MODEL

PARTS

LABOR

COMPRESSOR

DWC-121R

1 year

1 year

5 years

DWA-150R

Note: The warranty service center list is constantly changing with the addition of our

current qualified service centers. If there is inadequate or no local service facility,
subject individual customer will call DAEWOO on the toll free number 
1-800-DAEWOO8(1-800-323-9668) to be provided with further informations.

Summary of Contents for DWC121R1

Page 1: ...7 Wait at least 3 minutes before restarting the unit or in the case of power failure If you turn on the unit within 3 minutes after power off this can cause damage to the unit 8 If the air conditione...

Page 2: ...9 4 OPERATION INSTRUCTIONS 10 15 DISPLAY REMOTE CONTROL HOW TO INSERT BATTERIES 5 GENERAL INFORMATION 16 AIR FLOW AROUND UNIT DRAIN HOLE AND WATER DRIPPING OUTSIDE HOW TO INSTALL THE DRAIN CAP DOOR VE...

Page 3: ...me familiar with the operation of your room air conditioner After installing the unit re read these instructions to make sure you have completed each step and all parts are fastened in place for a sec...

Page 4: ...to the National Electric Code and applicable local code BEFORE INSTALLATION Test Run Unit Plug unit into proper power supply outlet Refer to operating instructions in this manual for comfortable livin...

Page 5: ...ch 914mm wide 3 Mark the center of Window sill with pencil 4 Insert Screws Type A into the sill bracket 5 Attach Sill bracket to window sill using two Screws Type B by each bracket The outside edge of...

Page 6: ...he Front Grille until it is separated from the chassis 4 Push base side of the Front Grille to upper side until it is separated from the chassis 4 Remove the part which protect orifice 1 After front g...

Page 7: ...will prevent raising of the window from the outside If you have a hard wood or metal window frame a 1 8 inch pilot hole may be needed in order to drive the screws 8 Attach the Window Seal A to window...

Page 8: ...Chassis holes Be careful the end of ventilation bar is to be located in the gap of blade 5 Fasten Front Grille with screws 6 Insert Filter into the Front Grille Step 8 Recheck the entire installation...

Page 9: ...3 CABINET 4 BLADE VERTICAL 5 PANEL CONTROL 6 REMOTE CONTROLLER NO PART NAME 7 BLADE HORIZENTAL 8 AIR VENT 9 FRAME GUIDE TOP 10 FRAME WINDOW KIT 11 SHUTTER WINDOW NAMES OF MAJOR COMPONENTS DWC 121R DW...

Page 10: ...SET It is the button to set the desired room temperature The temperature can be set within a range from 16 C 60 F to 32 C 90 F by 1 C 1 F POWER ON OFF SWITCH To turn the unit ON push this button To tu...

Page 11: ...erytime you push this button the auto swing mode is toggled TEMPERATURE It is the button to set the room in the desired room temp The temp can be set within a range from 16 C 60 F to 32 C 90 F by 1 C...

Page 12: ...only 1 The desired room temperature is changed within a range from 16 C 60 F to 32 C 90 F by 1 C F 1 FAN SPEED is changed as follows by pushing FAN SPEED button HIGH MID LOW HIGH DISPLAY 1 Current roo...

Page 13: ...button 1hr 2hr 3hr 4hr 5hr 6hr 8hr 10hr 12hr 16hr 20hr 24hr cancel 2 Unit is off after timer is over 3 If you want to cancel timer push this button again at any time DISPLAY 1 Current room temperature...

Page 14: ...after 4 hours The desired Temp is increased 3 C 5 4 F for 4 hours Auto swing is selected Fan speed is set to LOW L2 MODE The unit works as follow Auto swing is selected Fan speed is set to LOW 2 Set p...

Page 15: ...t the and directions are correct Be sure that both batteries are new Re attach the cover Slide it back into position Do not use rechargeable batteries such batteries differ from standard dry cells in...

Page 16: ...be installed level or tilted slightly to the outside for proper water disposal On exceptionally hot and humid days the air conditioner may permit excess water to pass thru rear drain hole or overflow...

Page 17: ...mild detergent solution 5 Cabinet may be washed with mild soap or detergent and lukewarm water then polished with liquid wax for appliances 6 Condenser and Evaporator coils should be cleaned at the be...

Page 18: ...to use an extension cord it is absolutely necessary that it will be a UL listed 3 wire grounding type appliance extension cord rated has a 3 blade grounding plug and a 3 slot receptacle that will plug...

Page 19: ...formation on wet surfaces Normal for operation in humid areas Suggested Solution Confirm power cord is plugged in Verify main power switch main circuit breaker or fuse of the unit is good Wait 3 to 4...

Page 20: ...changed This warranty is in lieu of all warranties expressed or implied and no representative or person is authorized to assume for us any other liability in connection with the sales of our electron...

Page 21: ...INDOW TYPE ROOM AIR CONDITIONER Please read carefully and thoroughly this manual before operating the unit If you still have any difficulties or problems consult your dealer for help or ELECTRONICS Pl...

Reviews: