41
3) H5 Error - Water temperature error in wool/ delicate course
ῡ
In case water temperature in wool/ delicate course is 45
ᴱ
or higher
ῢ
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
ΰ
Error display is cleared when turning off/ on power.
4) H6 Error - Abnormality in washing heater
ῡ
Within 15 minutes after heater operation begins;
In case standard temperature is of 42
ᴱ
or lower: If temperature does not increase by 2
ᴱ
or more In
case standard temperature is higher than 42
ᴱ
: If temperature does not increase by1
ᴱ
or more
ῢ
If temperature falls below standard temperature by 2
ᴱ
or more due to re-supply of water, etc.,
standard temperature is reset as the current temperature and error check time of15 minutes is reset.
ΰ
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
ῤ
Error display is cleared when turning off/ on power.
5) H8 Error - Washing heater overheating
ῡ
In case washing heater temperature increases by 5
ᴱ
or more within 30 seconds when there is no
water in tank, etc.
ῢ
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
ΰ
Error display is cleared when turning off/ on power.