FUNCTION

POWER ON

Push POWER button

COOLING MODE

Push the ‘MODE’ button until
‘COOLING’ lamp lights.

Change desired room
temperature

Push the ‘TEMP

▲▼

’ button.

Change ‘FAN SPEED’

Push the ‘FAN SPEED’
button.

OPERATION

1. The unit starts working. 

(It is delayed 3 minutes after main
power source is supplied.)

2. Default mode is ‘COOLING’ mode.
3. Default desired room temperature is

‘26°C’ (79°F).
And fan speed is ‘HIGH’.

1. Operating modes are changed as

follows by pushing “MODE” button.
(COOLING

TURBO

FAN

COOLING)

2. The compressor and fan work.
3. In this mode you can change fan

speed and desired temperature at
any time.

4. SLEEP mode and ON/OFF TIMER

can be selected.
(By remocon button only)

1. The desired room temperature is

changed within a range from 16°C
(60°F) to 32°C (90°F) by 1°C (°F)

1. FAN SPEED is changed as follows

by pushing “FAN SPEED” button.
(HIGH

LOW

HIGH)

DISPLAY

1. Current room temperature is

displayed.

2. ‘COOLING’ lamp lights.
3. ‘ROOM TEMP’ lamp lights.

1. Current room temperature is

displayed.

2. ‘COOLING’ lamp lights.
3. ‘ROOM TEMP’ lamp lights.

1. It display desired room temperature

when ‘TEMP’ button is pushed.

2. ‘DESIRED TEMP’ lamp lights.

3. After a few seconds, display is

changed to current room
temperature and ‘ROOM TEMP’
lamp lights.

1. It displays as follows.

2. After a few seconds, display is

changed to current room
temperature. 

ROOM TEMP

DESIRED TEMP

FAN

TURBO

COOLING

TIMER

ENERGY
SAVE

HIGH

LOW

POWER

MODE

TEMP

MODE

TEMP

FAN

SPEED

FAN SPEED

or

or

or

or

ROOM TEMP

DESIRED TEMP

FAN

TURBO

COOLING

TIMER

ENERGY
SAVE

ROOM TEMP

DESIRED TEMP

FAN

TURBO

COOLING

TIMER

ENERGY
SAVE

12

Summary of Contents for DWC-084R

Page 1: ...7 Wait at least 3 minutes before restarting the unit or in the case of power failure If you turn on the unit within 3 minutes after power off this can cause damage to the unit 8 If the air conditione...

Page 2: ...MAJOR COMPONENTS 9 4 OPERATION INSTRUCTIONS 10 15 DISPLAY REMOTE CONTROL HOW TO INSERT BATTERIES 5 GENERAL INFORMATION 16 CHANGING AIR FLOW DIRECTION AIR FLOW AROUND UNIT DRAIN HOLE AND WATER DRIPPING...

Page 3: ...ado para familiarizarse con la operaci n en el cuarto del aire condicionado After installing the unit re read these instructions to make sure you have completed each step and all parts are fastened in...

Page 4: ...to the National Electric Code and applicable local code BEFORE INSTALLATION Test Run Unit Plug unit into proper power supply outlet Refer to operating instructions in this manual for comfortable livin...

Page 5: ...Mark the center of Window sill with pencil 4 Insert Screws Type A into the sill bracket 5 Attach Sill bracket to window sill using two Screws Type B by each bracket The outside edge of window bracket...

Page 6: ...ase left lower snap fit Push the left lower side of chassis to the right with pushing right side of Front Grille to the right until the snap fit is released 3 Pull lower side of the Front Grille until...

Page 7: ...is will prevent raising of the window from the outside If you have a hard wood or metal window frame a 1 8 inch pilot hole may be needed in order to drive the screws 8 Attach the Window Seal A to wind...

Page 8: ...ille s hook to each Chassis holes 4 Fasten Front Grille with screws 5 Insert Filter into the Front Grille 6 Attach the inlet grill to the front grille Step 8 Recheck the entire installation WALL Screw...

Page 9: ...LADE HORIZENTAL 4 KNOB BLADE 5 GRILLE FRONT 6 INLET GRILLE NO PART NAME 7 AIR FILTER 8 PANEL CONTROL 9 FRAME GUIDE TOP 10 FRAME WINDOW KIT 11 SHUTTER WINDOW 12 REMOTE CONTROLLER NAMES OF MAJOR COMPONE...

Page 10: ...H To turn the unit ON push this button To turn the unit OFF push this button again MODE SELECT Everytime you push this button It is selected as follow COOLING TURBO FAN COOLING FAN SPEED Everytime you...

Page 11: ...button it is selected as follow COOLING TURBO FAN COOLING ENERGY SAVE Whenever you push this button the cumulative power consumption is decreased TEMPERATURE It is the button to set the room in the de...

Page 12: ...d room temperature is changed within a range from 16 C 60 F to 32 C 90 F by 1 C F 1 FAN SPEED is changed as follows by pushing FAN SPEED button HIGH LOW HIGH DISPLAY 1 Current room temperature is disp...

Page 13: ...3hr 4hr 5hr 6hr 8hr 10hr 12hr 16hr 20hr 24hr cancel 2 Unit is off after timer is over 3 If you want to cancel timer push this button again at any time DISPLAY 1 Current room temperature is displayed...

Page 14: ...el L1 Mode The unit is off after 4 hours The desired Temp is increased 3 C 5 4 F for 4 hours Fan speed is set to LOW L2 MODE The unit works as follow Fan speed is set to LOW 2 Set proper desired room...

Page 15: ...t the and directions are correct Be sure that both batteries are new Re attach the cover Slide it back into position Do not use rechargeable batteries such batteries differ from standard dry cells in...

Page 16: ...flow is obstructed or deflected back into unit the compressor may cycle on and off rapidly causing early compressor failure DRAIN HOLE AND WATER DRIPPING OUTSIDE Locate drain hole at the rear or on t...

Page 17: ...ll may be wiped off with a cloth dampened in a mild detergent solution 5 Cabinet may be washed with mild soap or detergent and lukewarm water then polished with liquid wax for appliances 6 Condenser a...

Page 18: ...wever if you still elect to use an extension cord it is absolutely necessary that it will be a UL listed 3 wire grounding type appliance extension cord rated has a 3 blade grounding plug and a 3 slot...

Page 19: ...formation on wet surfaces Normal for operation in humid areas Suggested Solution Confirm power cord is plugged in Verify main power switch main circuit breaker or fuse of the unit is good Wait 3 to 4...

Page 20: ...changed This warranty is in lieu of all warranties expressed or implied and no representative or person is authorized to assume for us any other liability in connection with the sales of our electron...

Page 21: ...INDOW TYPE ROOM AIR CONDITIONER W1 R C US LISTED UL and CUL listed Please read carefully and thoroughly this manual before operating the unit If you still have any difficulties or problems consult you...