![Daewoo DWB-180C-R Service Manual Download Page 9](http://html1.mh-extra.com/html/daewoo/dwb-180c-r/dwb-180c-r_service-manual_3413218009.webp)
8
7. TROUBLE SHOOTING GUIDE
TROUBLE
SITUATION
ANALYSIS
CAUSE
REMEDY
Fan motor and
compressor do not run
Switch is in "cool"
position but the
compressor does not
run
1. Power failure
2. Power is supplied,
but the equipment
does not run
1. Not operating at all
2. Compressor
3. Frequent start and
stop
1) Power plug
2) Circuit breaker
1) receptacle
2) Operation switch
3) Cord or lead wire to
the switch
1) Compressor
2) Thermostat
3) Selector switch
4) O.L.P
5) Capacitor
1) Electricity
2) Room temperature
and outside
temperature
3) Compressor
4) O.L.P
5) Capacitor
1) Thermostat
2) Capacitor
3) O.L.P
1) Power failure
2) Circuit breaker is tripped
3) Power plug is not contacting
Disconnection
Mechanical failure of switch
1) Disconnection
2) Malfunction of contact
Disconnection or burned-out
1) Failure
2) Malfunction
3) Knob is not set to the proper
setting
Failure of malfunction of proper
setting
1) Turn over
Lack of capacity
Disconnection
1) The voltage exceeded allowed
range
2) Capacity of wire is not
sufficient
Extremely high
Burned-out
Malfunction
Lack of capacity
Malfunction
Lack of capacity
Turn over
Consult your electric company
In case of a breaker, turn it on
and off a few times
Replace the power plug
Repair or replace the
receptacle
Replace the cord or lead wire
Replace the compressor or
connection wire
Replace
Repair or replace
Turn knob for cooler setting
Repair or replace the swtting
Wait until return it.
Replace
Repair
Consult your electric company
Check the capacity of wire
Ventilate well and remove the
heat source
Replace
Replace
Replace
Replace
Replace
Wait until return it.
Summary of Contents for DWB-180C-R
Page 20: ...DWB 180C R DWB 240C R DWA 180C R DWA 240C R...
Page 21: ......
Page 22: ...DWA 181C...
Page 23: ......